Troubleshooting
LA85 port tester
166
Maintenance Procedures
December 2003
The port tester is equipped to check 110-type wall field hardware with the three 1-pair patch cords that
are color-coded blue (1), orange (2), or green (3).
NOTE:
If the wall field has 66-type blocks, a 66-type block adapter (Comcode 405546474) is
needed.
!
DANGER
:
The port tester should not be plugged into an active circuit for an extended period of
time. Resistors in the tester can burn out.
LED indications for the various port types are listed in
Table 58, LED indications for the LA85 port
on page 167. Abbreviations are as follows:
•
R = Red
•
G = Green
Table 57: Port fault isolation using the LA85 port tester
To begin the
isolation
procedure
at the...
You might need this
preliminary information
or equipment...
And if...
Then...
Wall field in
equipment
room
Use display errors command
Off-board
errors indicated
Verify wiring from switch to
equipment room wall field.
Station
(terminating
end)
1
Unplug station cord
from terminal and plug
it into the “BRI” or
“Other” jack on the
tester, as applicable.
2
If the readings are OK,
the terminal, handset, or
handset cord may be
faulty.
Station
wall jack
1
Wrong or incorrect
reading from the
terminal end of the
station cord
2
D8W line cord
(Comcode
103786761) used at
station wall jack
If the reading from the jack is
OK, then the terminal cord may
be faulty.
Intermediate
closet wall
field
Isolate part of the wiring span,
either to the switch or to the
terminal
Содержание CMC1
Страница 1: ...Maintenance Procedures 555 245 103 Issue 1 1 December 2003 ...
Страница 14: ...Contents 14 Maintenance Procedures December 2003 ...
Страница 158: ...Server initialization recovery and resets System resets 158 Maintenance Procedures December 2003 ...
Страница 416: ...Additional maintenance procedures IP Telephones 416 Maintenance Procedures December 2003 ...
Страница 426: ...Index X 426 Maintenance Procedures December 2003 ...