2.4 Technical specifications
2.4.1 General specifications
The WTG manufacturer must also provide
any additional relevant warnings, instructions and / or
training specific to the integration of the service lift
required for its safe and correct installation.
Service lift
OCTOPUS XL120
Main door type
Full sliding door
1)
Service lift speed
18 m/min ± 10 % (50 Hz)
21 m/min ± 10 % (60 Hz)
Rated load
300 Kg
Lift weight (max.)
242 kg. (one SD conf.) / 250 kg. (two SD conf.)
Max. no. of persons
3 persons
Max. traveling height
160 m
Max. noise level
80 dB (A)
Power supply type
400V (50/60Hz) 3 Phase + N + PE
690V (50/60Hz) 3 Phase + PE
(1)
Optionally, depending on WTG configuration,
cabin could feature 2 full sliding doors (one on
the left, one on the right).
Operating temperature
-15 ºC - +60 ºC
Survival temperature
-25 ºC - +80 ºC
A low temperature kit is also available.
Operational temperature for low temperature:
-25 ºC - +40 ºC
NOTICE
Depending on national regulations, it may be
necessary for a third party to approve the final
installation.
NOTICE
The tower manufacturer’s risk assessment must
include a service lift integration study.
6
Guiding system
Aluminum ladder
Main door interlock system
Gu
ard locking