Cause
Solution
THE SERVICE LIFT DOES NOT MOVE UP OR DOWN.
A5 Power failure
Switch is not activated.
Turn the emergency stop button clockwise until it is released.
Grid voltage interrupted.
Find the cause and wait for the power to return.
Power supply between grid connection and control interrupted.
Test and if necessary repair the power cable, fuses, connections,
and/or wiring from the control box.
A6 Functions of limit switch
The emergency top limit switch has been pressed.
Door switch is not properly closed or is defective.
A top or bottom hatch switch is triggered.
Performamanualdescentuntiltheemergencytoplimitswitchis
released.
Close the door and test the door switch
.
Close the hatch.
A7 Protection switch overheated.
A phase is missing.
Test/repair fuses, power supply and connection.
Motor is not cooling.
Clean the hood.
Voltage too high/low.
Measure voltage and power consumption on the loaded motor. If
the voltage deviates from specifications, use a cable with in-
creased dimensions.
A8 Brake does not open (no click on ON/OFF).
Power supply, braking coil or rectifier defective.
Braking rotor closes.
Have a
certified technician, re
pair / replace the power supply,
braking coil and rectifier.
Return the traction hoist for repair.
A9 Guard locking switch and / or lock control box
If guard locking system is provided, the guard locking switch
and / or interlock control box is/are defective.
Test / repair defective components.
A10 Trapped-key system
The fence door trapped-key system is active.
The system switch is OFF.
Turn the trapped key to the ON position.
A11 Main switch
The main switch is in the OFF position.
Turn the main switch ON.
A12 Rescue pendant control
Rescue pendant control is plugged.
2
7
Use rescue pendant control in case of rescue event.
Otherwise, unplug pendant control.