background image

3.2.3 Interior light
3.2.3.1 Service light

The  service  lift  is 

optionaly 

equipped  with  a  light 

inside  the  cabin.  When  service  lift  is  connected  to 
power supply, this light illuminates at all times. 

3.2.3.2 Service light with emergency function

Optionaly  the  internal  light  is  battery  packed  in  order 
to illuminate the inside of the cabin in case of a power 
failure.  When  fully  charged,  it  will  last  at  least  for  90 
minutes. 

3.2.4 Anchor points

The  service  lift  features  three  anchor  points  inside  the  
cabin.

An additional anchor point is available to be used when 
the user egress or ingress through bottom hatches.

Figure 

7

: Anchor points

  DANGER

The lower anchor point must only be used for 
evacuation/rescue operation.

Fasten kit

M1

6

 nut

3.3 Traction system

3.3.1 Traction hoist M

6

08 

Avanti  M

6

08  traction hoist is installed on the top ofthe

 

cabin. It is an electrical powered hoistthat  powers  the

 

service  lift  up  and  down  along  a  traction  wire

 

rope.  It  consists  of  a  motor  a gearbox  and  a traction

 

system.

 

 

 

3.3.1.1 Electromagnetic motor brake

The  M

60

8  traction  hoist  is  equipped  with  an

 

electromagnetic  spring-loaded  brake  that  engages

 

automatically  when  releasing  the 

UP

  or 

DOWN

 

 

 

control  buttons,  or  following  a  power  failure.  Manual

 

release of this electromagnetic motor brake is allowed in

 

the  M

6

08  traction  hoist.  Once  the  electromagnetic

  

motor brake is released, the motor speed is controlled by a

 

centrifugal  brake  installed  between  the  motor shaft

 

 

 

 

 

and the gearbox. 

 

 

 

 

3.3.1.2 Overload detection device

An  overload  detection  device  is  built  into  the

 

traction  hoist.  Incase  of  an  overload,  it  will  prevent  the

 

upward 

travel    of 

the 

service 

lift 

(by

 

interrupting  control)  and  a    buzzer  will 

sound,

 

until overload condition is eliminated.

 

 

 

 

3.4 Fall arrest device

3.4.1 ASL

6

08 Fall arrest device 

The service lift is equipped with the ASL

6

08 fall arrest

 

device which will be triggered in case of an overspeed

 

condition.

 

 

 

The speed of the safety wire rope passing through the

 

device  is  continuously  monitored,  and  the  jaws

 

automatically  close  in  the  event  of  sudden  excessive

 

speed.

 

 

 

This  device  protects  the  service  lift  against  traction

 

wire rope breakages or traction system failures.

 

 

 

 

The  fall  arrest  device  can  also  be  engaged  or

 

disengaged  manually  by  acting  directly  on  the  fall

 

arrest device levers.

 

 

 

 

3.4.2 Shock absorber

The  fall  arrest  device  is  equipped  with  a  shock

 

absorber system.

 

 

 

 

Its function is to relieve the impact force on the cabin

 

by means of the shock absorber displacement in case

 

of the fall arrest device activation.

 

 

 

 

3.2.5 Internal emergency ladder

The service lift features an internal emergency ladder that 
is part of the main frame of the service lift.

In case of emergency, this internal ladder allows users to 
reach  the  top  hatch  and  accesing  to  ladder  and  ladder 
rail.

 

  NOTICE

Optional f

eature.

11

3.2.6 Fasten kit

The  service  lift  features  as  option  a  special  tool,  called 
Fasten  kit,  for  mechanically  blocking  the  lift  in  order  to 
perform  installation/maintenance  tasks  below  the 
suspended cabin. This kit is located inside the cabin (see 
Figure 8). It consists in two M16 screwed rods, that must 
be inserted through the holes of the top and bottom rollers 
assembly and along rungs of the guiding ladder, and finally 
blocked each with a M16 nut.

 

  WARNING

The internal emergency ladder cannot be used as 
anchor point for user’s PPE’s

 

M1

6

 screwed

 rod

 

Figure 

8

: Fasten kit

Содержание OCTOPUS XL120

Страница 1: ...AVANTI SERVICE LIFT Model OCTOPUS XL120 Service Lift User manual Original instructions AT00015389 English EN User Manual Service Lift Model OCTOPUS XL120 3rd Edition July 2019 Revision 1 30 07 2019...

Страница 2: ......

Страница 3: ...structions from Avanti iii has been subjected to abuse neglect casualty or negligence iv has been furnished by Avanti to Customer without charge or v has been sold on an AS IS basis Except as specifi...

Страница 4: ...Service Lift Doors 10 3 2 2 Wire inspection cover 10 3 2 3 Interior light 11 3 2 4 Anchor points 11 3 3 Traction system 11 3 3 1 Traction hoist M608 11 3 4 Fall arrest device 11 3 4 1 ASL608 Fall arr...

Страница 5: ...tomatic send configuration 22 4 3 8 Overload detection device 23 4 3 10 Fall arrest device 24 4 3 9 Manual descent 24 4 5 Troubleshooting 26 4 6 Out of service 29 Appendix User log sheet 30 Appendix S...

Страница 6: ...harness shock absorber lanyard and slider at all times and carry 2 way communication systems depending on local regulation The service lift is designed for a useful life of 20 years with an approximat...

Страница 7: ...AUTION Avoid injury follow all instructions NOTICE The owner must verify the need for third party service lift inspections with the local authority and comply with specified standards 1 4 Terms and de...

Страница 8: ...systems including an interlock system on platform fence doors A rescue pendant control only mandatory if rescue route of service lift can be somehow blocked and in case of an external call control bo...

Страница 9: ...x traveling height 160 m Max noise level 80 dB A Power supply type 400V 50 60Hz 3 Phase N PE 690V 50 60Hz 3 Phase PE 1 Optionally depending on WTG configuration cabin could feature 2 full sliding door...

Страница 10: ...4 55 M608 400V 50Hz M608 690V 50Hz M608 400V 60Hz M608 690V 60Hz 2 4 3 Fall arrest device Service lift Fall arrest device Lifting capacity Triggering speed Safety wire Approx weight Version Type Kg lb...

Страница 11: ...2 5 Dimensions 2 5 1 Octopus XL120 Figure 3 Octopus XL120 dimensions 970 1200 2812 2635 8...

Страница 12: ...rollers 10 Hour counter Full sliding door x2 External controls Top obstruction device Safety wire rope Traction wire rope Travelling cable pulley Additional anchor point bottom hatches use Internal em...

Страница 13: ...re activated while the second sliding door D2 would be locked The second sliding door D2 only could be opened when Platform level detection switch S18 is activated while the first sliding door D1 woul...

Страница 14: ...revent the upward travel of the service lift by interrupting control and a buzzer will sound until overload condition iseliminated 3 4 Fall arrest device 3 4 1 ASL608 Fall arrest device The service li...

Страница 15: ...SL light red Platform indicator light green EMERGENCY STOP button internal Hour counter Shunt key for bottom obstruction switch Trapped key switch1 UP button external EMERGENCY STOP button external DO...

Страница 16: ...ch must be OFF before the generator is turned on 3 5 2 1 1 Automatic send configuration 3 5 2 1 1a Versions with guard locking 3 5 2 1 1b Versions with trapped key or electrical switch monitoring syst...

Страница 17: ...blocking the bottom hatch the rescuer is below service lift and the service lift is stopped halfway through a platform hole blocking rescue route since platform has no extra hatch CAUTION There shall...

Страница 18: ...ully covers bottom cabin face The cover is provided with a hatch in case of evacuation When bottom obstruction device is activated service lift will stop descent as a consequence of one of the bottom...

Страница 19: ...t ensures smoothness though providing necessary endurance Figure 21 Guiding system Guiding system 1 2 Guiding ladder Top guiding rollers Bottom guiding rollers 3 1 2 3 3 9 Cable management 3 9 1 Trave...

Страница 20: ...h monitoring system This interlocking mechanism is comprised of a mechanical locking unit and a switch unit When the switch is opened the power is removed so the service lift cannot move This system a...

Страница 21: ...ually check that the WTG installation components are mounted in accordance with the specifications and without any noticeable defects or missing components Platform control boxes Traction and safety w...

Страница 22: ...the fall arrest device functionality called the Stomp test The procedure is explained in the Stomp test TYZX IZOUT VVKTJO Top obstruction device 1 Activate the top stop by pressing it down The servic...

Страница 23: ...and hold the DOWN button on the bottom platform box 4 2 Prohibited uses DANGER Failure to comply with the prohibited uses is extremely dangerous for the physical integrity of the users When using the...

Страница 24: ...dder becomes totally accessible Outside the cabin To open top hatch pull it up Once top hatch is open access inside the cabin by means of the internal emergency ladder Figure 26 Top hatch Top hatch Th...

Страница 25: ...service lift do not get close to the hoistway To place the service lift on the floor after the bottom obstruction device has stopped the lift 1 Turn the override bottom obstruction device switch clock...

Страница 26: ...feature a guard locking system CAUTION When the UP or DOWN button is pressed on the platform control box the response of the cabin is delayed During this delay an acoustic signal will sound and the wa...

Страница 27: ...uction device will not get damaged 10 BMM BSSFTU EFWJDF The service lift is provided with the ASL608 fall arrest device which will be triggered in case of an overspeed condition This device protects t...

Страница 28: ...OSED TO DYNAMIC LOADS WHEN A FALL IS PREVENTED 7HEN THE SERVICE LIFT HAS RETURNED TO THE BOTTOM PLATFORM TEST THE fALL ARREST DEVICE FUNCTIONALITY 2EPLACE ANY DEFECTIVE COMPONENTS OF THE FALL ARREST D...

Страница 29: ...safety of the service lift Replace immediately Cause Solution THE SERVICE LIFT DOES NOT MOVE UP OR DOWN A1 Emergency stop The fixed EMERGENCY STOP button has been activated In the user control box or...

Страница 30: ...otor is not cooling Clean the hood Voltage too high low Measure voltage and power consumption on the loaded motor If the voltage deviates from specifications use a cable with in creased dimensions A8...

Страница 31: ...ion switch is defective or not connected properly Test the bottom obstruction switch connection and functionality Replace the bottom obstruction switch if necessary The bottom obstruction switch is ac...

Страница 32: ...for advice and potential repair of hoist THE MOTOR HUMS LOUDLY OR THE WIRE ROPES SQUEAK BUT THE LIFT CAN GO BOTH UP AND DOWN G Wire ropes Wire ropes are dirty If possible immediately replace the trac...

Страница 33: ...TE HEIGHT OF M FT ABOVE THE BOTTOM LANDING FLOOR PLATFORM 4EST 7ITH THE CABIN PARKED AT AN APPROXIMATE HEIGHT OF M FT ABOVE THE BOTTOM LANDING FLOOR THE USER STARTS DESCENDING USING ELECTRIC CURRENT B...

Страница 34: ...del Octopus XL120 01 02 04 2018 Added Traction hoist M608 and ASL608 02 01 03 2019 EC Certificate updated Manufacturer updated to Avanti Wind Systems Technology S L 35 02 02 06 2019 Certification manu...

Страница 35: ......

Страница 36: ...www avanti online com...

Отзывы: