1
7
2
3
Figure
23
: Trapped-key system
Trapped-key system
1
Key
2
Safety lock
3
Actuator
1
3.10.1.2 Guard locking system
The platform fence door could be equipped with an
interlock system that keeps the door locked while the
service lift is not at the platform. The door becomes
unlocked when the service lift is at the platform with the
lift detection switch activated. From the moment the fence
door is open, power is removed so the service lift cannot
move. When the door is closed, the ready light is on.
During emergency use, for example during a power
outage, where evacuation or rescue is necessary, the door
guard locking switch can be unlocked by acting the
mechanical Door Manual Release system from outside the
fence, or from inside the fence.
This system is installed in place of the Trapped-key
system.
NOTICE
Optional function.
NOTICE
A locking system
is
compulsory for CE versions if
the platform fences have
doors.
3.10.1.3 Electrical switch monitoring system
An
optional
system
is
the
electrical
switch
monitoring system. This interlocking mechanism is
comprised of a mechanical locking unit and a switch
unit. When the switch is opened, the power is removed
so the service lift cannot move. This system allows users
to evacuate to the ladder more easily, without having to
jump over the fence. In this case, the fence doors must be
self-closing doors, to avoid any user could fall from a
platform if the fence door is left open.
3.11 Information signs and documents
The following documents, signs and stickers are supplied
with the service lift and must be always available.
Verify the integrity and legibility of all illustrations and
information signs. Replace any illustrations or signs that
are missing or an illegible.
Location
Documentation
Cabin
Serial number plate (including CE mark)
Manuals inside blue bag
Quick guide
Evacuation guide
Use of PPE label sign
Max. load / Nº persons label
Non standing on top label
Manual descent label
User/Main
control box
Main door guardlocking labels
Electrical hazard warning label
Wiring diagram inside blue bag
Not anchor point label
Bottom platform
fence
Rescue guide
Rescue pendant control emergency sign
Fasten kit label (if available)
Figure 2
4
: Platform position switch
Содержание OCTOPUS XL120
Страница 2: ......
Страница 11: ...2 5 Dimensions 2 5 1 Octopus XL120 Figure 3 Octopus XL120 dimensions 970 1200 2812 2635 8...
Страница 35: ......
Страница 36: ...www avanti online com...