Avant 860i
Service and maintenance
121
WARNING
Risks of short-circuit and
exposure to battery acid and
lead - Before handling the
battery, see safety instructions
about handling the battery on
page 19.
Check the condition and fastening of the battery,
the battery disconnect switch, and its cables
1.
Inspect and clean the battery terminals
regularly. If the terminals appear to be
corroded, clean them.
2.
Make sure that the battery is correctly
fastened and secured against movement. A
battery that moves can damage the electric
cables and cause short-circuit.
3.
Ensure that you use a battery that is correct
size and form so that it can be fastened
correctly. Use only a battery that meets the
specifications of the original battery.
4.
Clean the battery and its surroundings
carefully. Also remove the dirt from under
and around the battery periodically.
Disconnect (isolate) the battery
first by using the battery
disconnect switch.
Battery and its terminals contain
lead. Before handling the battery,
see safety instructions regarding
handling of the battery on page
19.
The battery is sealed and maintenance free,
meaning that it doesn't need and can’t be refilled with
water during its lifetime. Do not attempt to open the
cover of the battery.
WARNING
Risk of fire - Make sure the
battery is secured against
movement.
The insulators of
cables of a moving battery may get
damaged, causing risk of fire,
short-circuit, and sparks. A moving
battery can also short-circuit due to
contact between battery pole and
the frame of the loader. Battery
can get damaged due to
movements. Always ensure that
the battery is securely fastened
from its base flange. Keep the
battery and its surrounding area
clean so that dirt or other material
does not damage the battery.
Check electric cables of the loader
Check other electric cables and their routing and
fastening. If you see signs of damage on electric
cables or components, stop using the loader and
disconnect the battery. Replace the cables and
insulators before you continue to use the loader.
1.
Make sure that the cables in the engine
compartment cannot chafe against any sharp
edges. Correct the routing and fastening of
cables, if necessary. Replace damaged
cables.
2.
Check how the cables are routed through the
articulation joint of the loader. The cables
should not be pinned in between hydraulic
hoses, and the cables should not chafe
against other parts of the loader.
3.
Check cables for signs of aging and wear. If
a cable or its insulation has damaged, worn,
or become brittle, there is an increased risk
of short-circuit and fire.
4.
Check the condition and fastening of the
battery disconnect switch and its cables.
When the battery disconnect switch is in
position OFF, turn the ignition key to test the
disconnect switch. If the disconnect switch is
damaged, disconnect battery cables
immediately and replace the switch.
Содержание STAGEV 860i