background image

For product information and a complete list of distributors, please go to our web site:         

www.avagotech.com

Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries.
Data subject to change.  Copyright © 2005-2010 Avago Technologies. All rights reserved.  
AV02-1832N - December 21, 2010

Eye safety

The transmitter device emits light with a wavelength of 
650 nm (red). This product is designed to avoid damage to 
the unprotected eye. To indicate the classification of the 
light source, a label as depicted in figure 10 can be used. 
However these labels are not mandatory on the product 
according to IEC 60825 version 1.2 paragraph 1.1. 

Figure 8. Temperature measurement point

Figure 9.  LED source label

0.8

Temperature Measuring Point GND PIN
max. Temp. : Tcase max = 105° C

Maximum Temperature at FOT

The maximum abient temperature must not exceed 95° C.

To guarantee the reliability of the AFBR-1012 transmitter 
and AFBR-2012 receiver the operation temperature has 
to be determined at a defined measurement point at the 
GND pin of the transmitter.

The maximum temperature at this particular measure-
ment point for an operating MOST transmitter must not 
exceed Tcase,max = 105° C. This temperature value is veri-
fied by measurements during HTOL qualification test.

The receiver has a lower operation temperature than the 
transmitter and therefore it is not necessary to consider 
the receiver temperature.

The temperature measurement point is defined in the 
center of the AFBR-1012 GND pin dambar as shown in 
Figure 8.

Отзывы: