background image

2

Floor Life and maximum storage time

The moisture sensitivity classification is MSL2a according 
to JEDEC J-STD-020D.

Unopened

 

moisture barrier bagged devices

 can be stored 

up to 12 months in an environment with a temperature 
between 5° C and 50° C and a relative humidity (RH) not 
exceeding 90%.

Unpacked devices can be kept in a production environ-
ment up to 4 weeks provided a temperature not exceed-
ing 30° C and a relative humidity (RH) not exceeding 60%. 
For higher temperatures in the production environment 
the floor life is shortened (see Table 1).

Table 1. MSL2a floor life

[1]

 

Normal

Accelerated Equivalent

4 weeks

5 days

≤ 30° C

≤ 60° C

60% RH

60% RH

[1]  Max. storage time without humidity protection pack/ after opening 

moisture barrier bag

Baking 

When the devices are inserted and soldered into a MOST

£

 

system up to four weeks after they have been taken out 
of the moisture barrier bag, then the moisture level in  
the mold material is low enough to ensure minimum 

 

mechanical stress while soldering. 

If the devices are kept on the production floor for more 
than four weeks as described in the last paragraph, it is 
advised to bake the devices before soldering. 

Baking is done by removing the devices from the tube and 
placing them in a shallow container so that the package 
bodies do not touch each other. Then the devices are 
placed in the bake oven, heating the devices to 100° C for 
24 hours. After this procedure, the moisture content of 
the devices is low and the moisture-induced stress during 
soldering is reduced. As a general guideline baking is 

 

recommended before every soldering attempt. 

The baking procedure can be done as often as necessary. 

Figure 4. Warning sign for an ESD protected area

Electrostatic Discharge (ESD) Protection  

The devices are sensitive to electrostatic discharges and 
therefore must be handled with care in an ESD protected 
area, indicated with the sign as shown in Figure 4.

An ESD event may damage or degrade the device perfor-
mance.

The standard DIN 61340-5-1 has to be considered. The fol-
lowing ESD preventions should be applied. Any smaller 
ESD prevention program might be unsuitable to prevent 
ESD damages.

x

ESD floors

x

ESD tables, ESD work surfaces and ESD storage facilities 
(e.g. trolleys and carts)

x

ESD wrist straps/connectors for wrist straps

x

ESD footwear and garments (cotton or special released 
materials)

x

ESD gloves or finger cots

x

ESD chairs

x

ESD tools (e.g. nippers)

x

ESD preventions at equipment parts (Equipment parts 
which may directly contact the device leads must be 
made of dissipative materials, wherever possible. If 
dissipative materials cannot be used for technical 
reasons, metals must be used whose natural non-
conductive surface layer is sufficiently thin (breakdown 
voltage <10 V). Conducting machine parts which may 
contact the device leads directly must be connected to 
ground without a series resistor. Electrical fields in the 
neighborhood of the device must not exceed 10

4

 V/m.

x

ESD packing materials

Отзывы: