Powering an AVM500-ES for the first time
6.2.1
Example #1 - NAI48-ES {ch1-16} to AVY16-ES100 {ch1-16}
If you want to route NAI48-ES channels directly to AVY16-ES100 inputs, you will see that you are facing a yellow cell. This
means that Netpatch found a connection between theses two devices through an AVM500-ES. As patch grid is collapsed 16
by 16 in this example, all you have to do is to click the yellow cell between NAI48 {ch1-16} and AVY16 {ch1-16}. The
software will do everything automatically!
Fig. 7: First step patch
The patch you’ve just made in yellow cell is represented by a star. This is the symbolic view for a patch through an AVM500-
ES. At the same time, Netpatch added the real path of audio channels:
-
One cross (direct connection) between NAI48 and AVM500-ES Port C.
-
One circle (AVM500 internal patch) between Port C and Port A.
-
One cross (direct connection) between Port A and AVY16-ES100.
Now, if you select AVM500-ES port {Ain}, and then you go to the “Matrix” tab, you will notice that internal digital audio matrix
was effectively patched as expected.
AVM500-ES User’s Manual v2.1
AuviTran 2010
15
Содержание AVM500-ES
Страница 1: ...AVM500 ES User s Manual 1 ...