background image

27 

  PLANAR-2D Electrical Wiring Diagram 

.

 

 

Содержание PLANAR-2D-12/24

Страница 1: ...www autoterm ru Air heater Installation Instructions PLANAR 2D 12 24 PLANAR 4DM2 12 24 P PLANAR 44D 12 24 GP P PLANAR 8DM 12 24 P...

Страница 2: ...6 Introduction 7 Application modification 7 Safety 8 Installation 9 PLANAR 2D Heater Dimensions 10 PLANAR 4DM2 Heater Dimensions 11 PLANAR 44D Heater Dimensions 12 PLANAR 8DM Heater Dimensions 13 Hea...

Страница 3: ...3 Connections Diagram Main Parts and units of PLANAR 2D...

Страница 4: ...4 Connections Diagram Main parts and units of PLANAR 4DM2 mod P...

Страница 5: ...5 Connections Diagram Main parts and units of PLANAR 44D mod P...

Страница 6: ...6 Connections Diagram Main parts and units of PLANAR 8DM mod P...

Страница 7: ...tion instructions contain the necessary information and advice on the installation of air heaters PLANAR 1 Application modification Application of air heaters Air heaters are designed to heat the driv...

Страница 8: ...shall not be connected to the electric circuit of the vehicle with its engine running and no battery installed Installation of the heater and its component parts shall be carried out by specialized o...

Страница 9: ...length of the output duct should not exceed 5 meters in total When mounting the heater care should be taken to ensure that its housing does not have harmful contact with projecting parts of the floor...

Страница 10: ...10 PLANAR 2D Heater Dimensions...

Страница 11: ...11 PLANAR 4DM2 Heater Dimensions...

Страница 12: ...12 PLANAR 44D Heater Dimensions...

Страница 13: ...13 PLANAR 8DM Heater Dimensions...

Страница 14: ...14 Heater Mounting Position...

Страница 15: ...15 Heater Mounting Position...

Страница 16: ...16 Heater Mounting holes...

Страница 17: ...Fig 13 Installation of air ducts to the air heater PLANAR 8DM is forbidden When using a mounting box outlet should be sealed in such a manner that the box itself did not get hot air 3 5 Combustion Ai...

Страница 18: ...operation of vehicle units The outlet of the exhaust pipe should be in such a position that would prevent clogging or entering of snow and also provide for free drain of any water that got into it Fo...

Страница 19: ...aust pipe outlet and the air intake shall not be placed on the opposite sides of the vehicle Fig 18 The correct installation of the exhaust and air intake pipes is on one side The distance between the...

Страница 20: ...20...

Страница 21: ...fuel tank is shown in Fig 19 The fuel tank needs to be mounted so that fuel which can be spilled when filling a fuel tank shouldn t be applied on an exhaust system and an electrical wiring Fuel fille...

Страница 22: ...mp is used for metered supply of fuel into the combustion chamber The fuel pump is operated by electrical impulses sent by the control unit The pulse frequency corresponds to the certain performance o...

Страница 23: ...r connection of two fuel tubes with a coupling is shown in Fig 25 Cutting of couplings and fuel tubes should be done only with a sharp knife Interfaces shall not be crushed and must be free of burrs o...

Страница 24: ...ing operation of the vehicle must be eliminated Harnesses are fastened to elements of the vehicle with plastic clips Attention Mounting shall be carried out with the fuse removed If the length of the...

Страница 25: ...fastened to the panel with screws The wire is led out of the Controller housing through the back cover The Controller snaps to the bracket with an audible click 3 9 8 Cab Sensor Installation Cabin se...

Страница 26: ...fuel supply line can be filled in two ways 1 to start a heater several times Time of one full start 5 minutes 2 to use the fuel pumping device Control of filling of the fuel supply line is exercised v...

Страница 27: ...27 PLANAR 2D Electrical Wiring Diagram...

Страница 28: ...28 Electrical Wiring Diagram PLANAR 44D PLANAR 4DM2 mod...

Страница 29: ...29 Electrical Wiring Diagram PLANAR 8DM mod...

Отзывы: