  3 Installation

 

 

Observe safety requirements during heater 
installation. 

 

3.1 Mounting Location 
The heater can be mounted both inside and outside the 

vehicle. 

For outside mounting the heater should be installed in 

an area protected from water and dirt. The heater should be 
mounted  in  such  a  way  that  it  is  not  exposed  to  water  at 
overcoming water obstacles by the vehicle. 

Heater dimensions are shown in Figures 5-8. 

 

3.2 Heater Installation 
Mounting  positions  should  be  in  accordance  with 

those shown in Fig.9-12. The intake of the heater should be 
positioned  in  such  a  way  that,  under  normal  operating 
conditions, exhaust gases of the engine or of the heater could 
not be sucked into it. 

During installation and operation of the heater, intake 

and outlet of the heater should be protected against foreign 
objects getting into them. 

When installing the air ducts to the heater, they should 

not have deformations, reducing the flow area of the duct. 
The maximum length of the output duct should not exceed 
5 meters in total. 

 

 

When mounting the heater, care should be taken 
to ensure that its housing does not have harmful 
contact with projecting parts of the floor or other 
parts of the cabin. 

 

 

Installation  of  air  ducts  to  the  air  heater 
PLANAR-8DM is forbidden 

 

3.3 Mounting Holes. 

For 

heaters 

PLANAR-2D, 

PLANAR-4DM2 

and 

PLANAR-44D,  holes  in  the  body  of  the  vehicle  should  be 
made  as  shown  in  Fig.12.  Heater  can  be  installed  using 
mounting brackets, see Fig.11 (in that case, longer studs should 
be installed in the heater). 

 

 

For  heaters  PLANAR-8DM,  holes  in  the  body  of  the 

vehicle (with the thickness of the body (floor) of not more than 
3mm) should be made as shown in Fig.12. 

With  the  thickness  of  the  vehicle  body  (floor)  of  more 

than 3мм, installation of the heater requires the following: 

1. To make a hole in the form of a rectangle with sides of 

180 x 95 mm in the body of the vehicle; 

2. To attach a mounting bracket to the heater (this bracket 

can be made of steel sheet at least 2.5mm thick, see Fig.12); 

3. To attach the exhaust pipe, air intake, and fuel line to 

the heater and fasten the whole assembly to the body of 
the vehicle 
 

 

 

Содержание PLANAR-2D-12/24

Страница 1: ...www autoterm ru Air heater Installation Instructions PLANAR 2D 12 24 PLANAR 4DM2 12 24 P PLANAR 44D 12 24 GP P PLANAR 8DM 12 24 P...

Страница 2: ...6 Introduction 7 Application modification 7 Safety 8 Installation 9 PLANAR 2D Heater Dimensions 10 PLANAR 4DM2 Heater Dimensions 11 PLANAR 44D Heater Dimensions 12 PLANAR 8DM Heater Dimensions 13 Hea...

Страница 3: ...3 Connections Diagram Main Parts and units of PLANAR 2D...

Страница 4: ...4 Connections Diagram Main parts and units of PLANAR 4DM2 mod P...

Страница 5: ...5 Connections Diagram Main parts and units of PLANAR 44D mod P...

Страница 6: ...6 Connections Diagram Main parts and units of PLANAR 8DM mod P...

Страница 7: ...tion instructions contain the necessary information and advice on the installation of air heaters PLANAR 1 Application modification Application of air heaters Air heaters are designed to heat the driv...

Страница 8: ...shall not be connected to the electric circuit of the vehicle with its engine running and no battery installed Installation of the heater and its component parts shall be carried out by specialized o...

Страница 9: ...length of the output duct should not exceed 5 meters in total When mounting the heater care should be taken to ensure that its housing does not have harmful contact with projecting parts of the floor...

Страница 10: ...10 PLANAR 2D Heater Dimensions...

Страница 11: ...11 PLANAR 4DM2 Heater Dimensions...

Страница 12: ...12 PLANAR 44D Heater Dimensions...

Страница 13: ...13 PLANAR 8DM Heater Dimensions...

Страница 14: ...14 Heater Mounting Position...

Страница 15: ...15 Heater Mounting Position...

Страница 16: ...16 Heater Mounting holes...

Страница 17: ...Fig 13 Installation of air ducts to the air heater PLANAR 8DM is forbidden When using a mounting box outlet should be sealed in such a manner that the box itself did not get hot air 3 5 Combustion Ai...

Страница 18: ...operation of vehicle units The outlet of the exhaust pipe should be in such a position that would prevent clogging or entering of snow and also provide for free drain of any water that got into it Fo...

Страница 19: ...aust pipe outlet and the air intake shall not be placed on the opposite sides of the vehicle Fig 18 The correct installation of the exhaust and air intake pipes is on one side The distance between the...

Страница 20: ...20...

Страница 21: ...fuel tank is shown in Fig 19 The fuel tank needs to be mounted so that fuel which can be spilled when filling a fuel tank shouldn t be applied on an exhaust system and an electrical wiring Fuel fille...

Страница 22: ...mp is used for metered supply of fuel into the combustion chamber The fuel pump is operated by electrical impulses sent by the control unit The pulse frequency corresponds to the certain performance o...

Страница 23: ...r connection of two fuel tubes with a coupling is shown in Fig 25 Cutting of couplings and fuel tubes should be done only with a sharp knife Interfaces shall not be crushed and must be free of burrs o...

Страница 24: ...ing operation of the vehicle must be eliminated Harnesses are fastened to elements of the vehicle with plastic clips Attention Mounting shall be carried out with the fuse removed If the length of the...

Страница 25: ...fastened to the panel with screws The wire is led out of the Controller housing through the back cover The Controller snaps to the bracket with an audible click 3 9 8 Cab Sensor Installation Cabin se...

Страница 26: ...fuel supply line can be filled in two ways 1 to start a heater several times Time of one full start 5 minutes 2 to use the fuel pumping device Control of filling of the fuel supply line is exercised v...

Страница 27: ...27 PLANAR 2D Electrical Wiring Diagram...

Страница 28: ...28 Electrical Wiring Diagram PLANAR 44D PLANAR 4DM2 mod...

Страница 29: ...29 Electrical Wiring Diagram PLANAR 8DM mod...

Отзывы: