9 Drive
58
© Copyright Reserved Autonics Co., Ltd.
9.3
Continuous Mode
At continuous mode, it operates motor continuously when drive signal inputs to the designated
direction.
When STOP signal inputs or limit signal of the direction inputs, it stops.
Continuous mode drive
1st
Drive mode
: “MD0”=0, “MD1”=1
2nd
Select start drive speed.
: It is available to set the start drive speed combining with
“SSP0”, ”SSP1”.
3rd
Select max. drive speed.
: It is available to set the max. drive speed combining with
“MSP0”, ”MSP1”.
4th
Drive: When
“+Run” or “–Run” signal inputs, it drives to CW direction or CCW
direction.
5th
Stop: When
“STOP” signal inputs or limit signal of the direction inputs, it stops.
6th
Emergency stop: When
“EMG” signal inputs, it stops emergently.
For continuous mode drive by I/O control,
“MD0/HMD0” turns OFF, “MD1/HMD1” turns ON, and
it selects continuous drive.
Содержание AiC Series
Страница 1: ...AiC Series User Manual AiC Series Controller Integrated 2 Phase Closed Loop Stepper Motor System ...
Страница 2: ...ii Copyright Reserved Autonics Co Ltd ...
Страница 12: ...Table of Contents xii Copyright Reserved Autonics Co Ltd ...
Страница 22: ...2 Specifications 22 Copyright Reserved Autonics Co Ltd ...
Страница 26: ...3 Dimensions 26 Copyright Reserved Autonics Co Ltd ...
Страница 31: ...5 Connection Copyright Reserved Autonics Co Ltd 31 5 Connection ...
Страница 32: ...5 Connection 32 Copyright Reserved Autonics Co Ltd ...
Страница 34: ...6 Characteristics 34 Copyright Reserved Autonics Co Ltd ...
Страница 54: ...8 Control Input Output 54 Copyright Reserved Autonics Co Ltd ...
Страница 70: ...10 Program Instructions 70 Copyright Reserved Autonics Co Ltd ...
Страница 86: ...11 Driver Function 86 Copyright Reserved Autonics Co Ltd ...