Parameter

Description

Value Range

Units

Default

98

Save to User Default Area

0–Do Nothing and Exit

1–Save Settings

0

99

Restore from User Default Area

0–Do Nothing and Exit

1–Restore Settings

0

P

araMeter

 D

escriPtiOns

Item

Parameter Name

Description

0

Exit to Running Mode

When parameter 0 is selected in Parameter-Selection Mode, the 

unit will return to Running Mode and display the running value�  

This should be selected once the changes to the parameters are 

completed�

Read-Only Identification Items

1

Model Number

This is a number which represents the base model number for the 

product�  The model code for the GSDA-DP-S is 90�

2

Software Build

The software build is a code which identifies the software version 

of the unit�

3

Hardware Version 

The hardware version is a code which identifies which hardware 

was used to build the unit�

4

Serial Number - Major (Reserved)

These parameters are reserved for future use as an electronic serial 

number and are unique to each manufactured unit�

5

Serial Number - Minor (Reserved)

General Setup

10

Generate/Scale

Mode 1: Generate–Generate Output Signal

Mode 2: Scale–Scale Input Signal

11

Display Intensity

This parameter adjusts the intensity of the LED display digits in 

the front panel of the unit�  The values of 0 – 31 correspond to a 

gradual change from very dim to very bright� 

12

Display Zero Blanking

This selects the number of display digits that are required to be 

displayed regardless of the display value� For example, with a 

Display Zero Blanking setting of 3 and a displayed value of 6, the 

display would show “_006”�

•  Mode 1: ___X 

Always show at least 1 digit

•  Mode 2: __XX 

Always show at least 2 digits

•  Mode 3: _XXX  Always show at least 3 digits

•  Mode 4: XXXX  Always show all 4 digits

13

Decimal Point Position

This selects the format of the display with respect to the decimal 

point’s position�  This parameter does not affect the value entry 

for other parameters�  For example, if the user desires to display 

numbers such as 12�34 or 1�05, then parameter 13 should be set 

to 2�

•  Mode 0: Fixed XXXX (DP disabled)

•  Mode 1: Fixed X�XXX

•  Mode 2: Fixed XX�XX

•  Mode 3: Fixed XXX�X

•  Mode 4: Fixed XXXX�

15

Keypad Mode

This parameter selects the operating mode of the front-panel push 

buttons�  In some applications, increasing or decreasing the scroll 

rate provides the user more controllability when entering settings�  

Parameters 14 and 15 affect only the Up and Down buttons when 

the user interface is in Running Mode�  

•  Mode 1: Linear, Constant Rate 

In linear mode, pressing and holding the Up or Down buttons 

will cause the display to continuously change value in the 

requested direction until either the Display Minimum or Display 

Maximum is reached�  The displayed value will scroll at a 

constant rate which is specified using parameter 16�

•  Mode 2: Non-linear, Accelerating Rate 

In non-linear mode, pressing and holding the Up or Down 

buttons will cause the display to continuously change value in 

the requested direction until either the Display Minimum or 

Display Maximum is reached�  The displayed value will initially 

scroll at a slow rate and increase in speed until the maximum 

scroll rate is achieved�  The initial scroll rate is specified using 

parameter 16�

Содержание IronHorse GSDA-DP-S

Страница 1: ...Page 1 IronHorse GSDA DP S User Manual 1st Edition 09 18 2019 GSDA DP S Signal Conditioner Generator User Manual User Manual Number GSDA DP S_UMP ...

Страница 2: ...onments requiring fail safe performance such as in the operation of nuclear facilities aircraft navigation or communication systems air traffic control direct life support machines or weapons systems in which the failure of the product could lead directly to death personal injury or severe physical or environmental damage High Risk Activities AutomationDirect specifically disclaims any expressed o...

Страница 3: ... 09 18 2019 Contents Warning 2 Trademarks 2 Publication History 2 GSDA DP S User Manual Overview 4 IronHorse GSDA DP S General Information 4 GSDA DP S Installation 6 GSDA DP S Operation 8 Device Configuration 9 Software Parameters 11 Troubleshooting 16 ...

Страница 4: ...n in the left hand margin the paragraph to its immediate right will be a special note WARNING When you see the exclamation mark icon in the left hand margin the paragraph to its immediate right will be a WARNING This information could prevent injury loss of property or even death in extreme cases IronHorse GSDA DP S General Information The GSDA DP S is a panel mounted multi purpose signal conditio...

Страница 5: ...essly excluded NOTE Carefully check the GSDA DP S for shipping damage Report any damage to the carrier immediately Do not attempt to install the device if visible damage is evident to either the circuit or to the electronic components Specifications GSDA DP S Specifications Electrical Line Input Voltage 85 265 VAC Line Input Frequency 48 62 Hz Voltage Signal Input 0 10 VDC Voltage Signal Output Mi...

Страница 6: ...CONTROL HOUSING APPROXIMATELY 3 622 WIDE BY 1 770 HIGH GSDA DP S CONTROL SUPPLIED WITH EACH CONTROL 1 GASKET 2 2 6 32 X 3 4 PANHEAD BLACK OXIDE STAINLESS SCREWS 3 2 6 NUT WITH LOCKWASHER Exploded Panel View Cut out and Mounting Dimensions HOUSING DEPTH 4 625 117 5 PANEL CUT OUT GSDA DP S x 2 GEN SCL SPL ENTER SIGNAL SCALER AND GENERATOR 4 00 101 6 3 62 91 9 0 885 22 5 1 77 45 0 140 3 6 4 00 101 6 ...

Страница 7: ...his terminal For systems with two hot AC lines connect either of the Hot AC lines to this terminal P3 3 SIGNAL IN In Scaled Mode connects to Negative or Common of voltage or current signal to be attenuated P3 4 SIGNAL IN In Scaled Mode connects to Positive of voltage or current signal to be attenuated P3 5 24VDC SUPPLY A 24VDC supply output is provided to the user for sensor or other device P3 6 2...

Страница 8: ...e only the display setting effects the 4 20mA current output level In voltage output mode the display setting and the maximum level set by the potentiometer R9 adjustment determine the voltage output level see Device Configuration for proper hardware and software setup SPL The GSDA DP S is in Set Point Lock this effectively disables any changes until IN1 IN2 input levels change according to the fu...

Страница 9: ...ed value is showing in the display window pressing the Enter button again will return to Parameter Mode The new value is not saved in permanent memory until the Enter button is pressed Removing power from the unit while in Value Mode may result in the specified new value being lost The front panel Annunciators will be perform as follows Parameter 10 1 Gen annunciator lit Parameter 10 2 SCL annunci...

Страница 10: ... 2 0 10 VDC Input Scaled 4 20 mA or 0 1 20VDC Output 3 No Input Generator 4 20 mA or 0 1 20VDC Output NOTE Both JP3 and JP4 must be set the same GSDA DP S Current Voltage I O Jumpers and Parameter 10 Settings Input Output Parameter 10 JP1 JP3 JP4 JP5 Scale Generate V I In V I Out Reference V I Out Power Supply Application Configuration Pin to Pin Jumper Configuration Current Voltage Scale li Vo Vo...

Страница 11: ...ult to Zero Display 2 Default to Power up Value 3 Default to Previous Running Value 3 19 Power Up Value 0 9999 Eng Units 0 Display and Output Setup Parameters 20 Display Value at Minimum Output 9999 9999 Eng Units 0 21 Display Value at Maximum Output 9999 9999 Eng Units 1000 25 Output Minimum 0 1000 1 10 0 26 Output Maximum 0 1000 1 10 1000 Input 1 IN1 Setup Parameters 30 IN1 Input Configuration 1...

Страница 12: ...example with a Display Zero Blanking setting of 3 and a displayed value of 6 the display would show _006 Mode 1 ___X Always show at least 1 digit Mode 2 __XX Always show at least 2 digits Mode 3 _XXX Always show at least 3 digits Mode 4 XXXX Always show all 4 digits 13 Decimal Point Position This selects the format of the display with respect to the decimal point s position This parameter does not...

Страница 13: ...parameters 21 Display Value at Maximum Output This parameter defines the upper end of the display range This is the value which limits how high the user is able to scroll the displayed value in Running Mode This parameter is set without consideration for the decimal point s position For example setting this parameter to 1000 would set the upper display limit at 100 0 1 000 or 1000 according to the...

Страница 14: ...esponds to the programmed jog setpoint parameter 31 Once the IN1 input returns to an electrically low state or wired to the unit s common the output will once again correspond to the display value Mode 5 Output 100 When IN1 Low When the IN1 input is at an electrically low state or wired to the unit s common the GSDA DP S will force its output to 100 Once the IN1 input returns to an electrically hi...

Страница 15: ...will once again correspond to the display value Mode 5 Output 100 When IN2 Low When the IN2 input is at an electrically low state or wired to the unit s common the GSDA DP S will force its output to 100 Once the IN2 input returns to an electrically high 5V state or allowed to float disconnected the output will once again correspond to the display value Mode 6 Output 100 When IN2 High When the IN2 ...

Страница 16: ...r additional help and instructions Display is dim Display intensity parameter is too low Increase the display intensity parameter to cause the display digits to become brighter S1 or S2 displayed Switch S1 or S2 is active Remove S1 or S2 input Refer to Parameter 30 and 35 for information on settings LOC displayed Parameter 30 or 35 is set to 7 Change input state of S1 or S2 or reprogram Parameter ...

Отзывы: