Page 11
IronHorse GSDA-DP-S User Manual – 1st Edition – 09/18/2019
S
oftWAre
P
ArAMeterS
Parameter
Description
Value Range
Units
Default
0
Select parameter 0 to return to Run
mode
n/a
–
n/a
Read-Only Parameters
1
Model Number
90 – GSDA-DP-S
90
2
Software Build
1–9999
n/a
3
Hardware Version
1–9999
n/a
4
Serial Number - Major (Reserved)
n/a
n/a
5
Serial Number - Minor (Reserved)
n/a
n/a
General Setup Parameters
10
Generate/Scale
1–Generate
2–Scale
1
11
Display Intensity
0–31 (Dim–Bright)
26
12
Display Zero Blanking
1–___X Show at least 1 digit
2–__XX Show at least 2 digits
3–_XXX Show at least 3 digits
4–XXXX Show at least 4 digits
2
13
Decimal Point Position
0–Decimals Disabled (XXXX)
1–X�XXX
2–XX�XX
3–XXX�X
4–XXXX�
3
15
Keypad Mode
1–Linear, constant rate
2–Non-linear, accelerating rate
2
16
Keypad Scroll Delay
0–30 (Fast–Slow)
10
18
Power-Up Mode
1–Default to Zero Display
2–Default to Power-up Value
3–Default to Previous Running
Value
3
19
Power-Up Value
0–9999
(Eng�
Units)
0
Display and Output Setup Parameters
20
Display Value at Minimum Output
-9999–9999
(Eng�
Units)
0
21
Display Value at Maximum Output
-9999–9999
(Eng�
Units)
1000
25
Output % - Minimum
0–1000
1/10 %
0
26
Output % - Maximum
0–1000
1/10 %
1000
Input #1 (IN1) Setup Parameters
30
IN1 Input Configuration
1–Output 0% when IN1 Low
2–Output 0% when IN1 High
3–Output Setpoint when IN1 Low
4–Output Setpoint when IN1 High
5–Output 100% when IN1 Low
6–Output 100% when IN1 High
7–Lock Set Point when IN1 Low
1
31
IN1 Setpoint
-9999–9999
(Eng�
Units)
0
Input #2 (IN2) Setup Parameters
35
IN2 Input Configuration
1–Output 0% when IN2 Low
2–Output 0% when IN2 High
3–Output Setpoint when IN2 Low
4–Output Setpoint when IN2 High
5–Output 100% when IN2 Low
6–Output 100% when IN2 High
7–Lock Set Point when IN2 High
1
36
IN2 Setpoint
-9999–9999
(Eng�
Units)
0
Parameter Memory Commands
95
Restore Settings to Factory Default
0–Do Nothing and Exit
5–Restore Factory Defaults
0