Port Specifications

Ethernet Specifications

Port Name

ETHERNET

Description 

Standard transformer isolated Ethernet port with built-in surge protection 

for programming, online monitoring, Email (SMTP client), Modbus/TCP 

client/server connections (fixed IP or DHCP), Ethernet IP client/server 

connections, Custom Protocol over Ethernet and ProNet.

Transfer 

Rate

10 Mbps and 100 Mbps (auto-crossover)

Port Status 

LED

LINK (Amber LED) is solid when network LINK is established. ACT 

(Green LED) flashes when port is active.

1 2 3 4 5 6 7 8

8-pin RJ45 Connector

(8P8C)

TD+

TD–

RD+

RD–

1

2

3

4

5

6

7

8

TD+

TD–

RD+

RD–

1

2

3

4

5

6

7

8

TD+

TD–

RD+

RD–

1

2

3

4

5

6

7

8

TD+

TD–

RD+

RD–

1

2

3

4

5

6

7

8

RJ45

RJ45

RJ45

RJ45

OR/WHT
OR
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN

OR/WHT
OR
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN

OR/WHT

OR

GRN/WHT

BLU

BLU/WHT

GRN

BRN/WHT

BRN

GRN/WHT

GRN

OR/WHT

BLU

BLU/WHT

OR

BRN/WHT

BRN

Patch (Straight-through) Cable

Crossover Cable

8

1

10/BASE-T/100BASE-TX

Micro USB Type B Slave Input Specifications

Port Name

MICRO USB

Description

Standard Micro USB Slave input for programming and online 

monitoring, with built-in surge protection. Not 

compatible with older full speed USB devices.

Transfer Rate

480 Mbps

Port Status LED

Green LED is illuminated when LINK is established to programming 

software.

Cables

USB Type A to Micro USB Type B:  
6ft cable part # USB-CBL-AMICB6
15ft cable part # USB-CBL-AMICB15

PGM

LINK

USB

1 VBUS
2 D-

3 D+

4 ID

5 GND

Содержание Productivity 1000 P1-540

Страница 1: ...red 24VDC 2 5W plus 1 25 W per additional I O module See page 6 for Power Supply options Recommended Fuse External Edison S5061 R Time Delay 1A Fuse Communications 4 Integrated Ports USB IN Programmin...

Страница 2: ...H MIN MAX P1 08TD1 Check all latches are secure after modules are connected CPU Front Panel P1 540 RUN STOP PWR RUN CPU REMOTE I O RS 232 RS 485 10 100 ETHERNET ACT LINK G T LINK ACT PGM LINK RX TX TX...

Страница 3: ...compartment located on the top of the CPU Step Two Insert battery and close compartment Squeeze tabs and pull battery holder up to remove battery P1 540 P1 540 Take care to insert battery behind tab...

Страница 4: ...Maximum 3 RXD RS 232 Input 4 TXD RS 232 Output 5 RTS RS 232 Output 6 GND Logic Ground RS 485 Port Specifications Port Name RS 485 Description Non isolated RS 485 port connects the CPU as a Modbus ASC...

Страница 5: ...RD 1 2 3 4 5 6 7 8 TD TD RD RD 1 2 3 4 5 6 7 8 TD TD RD RD 1 2 3 4 5 6 7 8 RJ45 RJ45 RJ45 RJ45 OR WHT OR GRN WHT BLU BLU WHT GRN BRN WHT BRN OR WHT OR GRN WHT BLU BLU WHT GRN BRN WHT BRN OR WHT OR GRN...

Страница 6: ...Conductor 28 16 AWG Stranded Conductor Screw Driver Width 1 8 in 3 175 mm Maximum Screw Size M2 Screw Torque 1 7 lb in 0 4 N m Productivity1000 Power Supplies All Productivity1000 PLC CPUs require 24...

Страница 7: ...7 Sales 800 633 0405 www productivity1000 com...

Страница 8: ...al codes that regulate the installation and operation of your equipment These codes vary from area to area and it is your responsibility to determine which codes should be followed and to verify that...

Отзывы: