General Specifications

Operating Temperature

0° to 60°C (32° to 140°F)

Storage Temperature

-20° to 70°C (-4° to 158°F)

Humidity

5 to 95% (non-condensing)

Environmental Air

No corrosive gases permitted 

Vibration

IEC60068-2-6 (Test Fc)

Shock

IEC60068-2-27 (Test Ea)

Heat Dissipation

3810mW

Enclosure Type

Open Equipment

Module Location

Controller connector on the side of the power supply in a 

Productivity1000 System.

EU Directive

See the “EU Directive” topic in the Productivity Suite Help 

File. Information can also be obtained at: 
www.productivity1000.com

Weight

136g (4.8 oz)

Agency Approvals

UL 61010-1 and UL 61010-2-201 File E139594, 
Canada & USA
CE (EN 61131-2 EMC, EN 61010-1 and EN 61010-2-201 

Safety)*

*See CE Declaration of Conformance for details.

WARNING:

 

To minimize the risk of potential safety problems, you should 

follow all applicable local and national codes that regulate the installation 

and operation of your equipment. These codes vary from area to area and 

it is your responsibility to determine which codes should be followed, and 

to verify that the equipment, installation, and operation are in compliance 

with the latest revision of these codes.

Equipment damage or serious injury to personnel can result from 

the failure to follow all applicable codes and standards. We do not 

guarantee the products described in this publication are suitable for 

your particular application, nor do we assume any responsibility for your 

product design, installation, or operation.

If you have any questions concerning the installation or operation of 

this equipment, or if you need additional information, please call Technical 

Support at 770-844-4200.

This publication is based on information that was available at the time 

it was printed. At AutomationDirect.com

®

 we constantly strive to improve 

our products and services, so we reserve the right to make changes to 

the products and/or publications at any time without notice and without 

any obligation. This publication may also discuss features that may not be 

available in certain revisions of the product.

8

Tech Support 770-844-4200

www.productivity1000.com

Содержание Productivity 1000 P1-540

Страница 1: ...red 24VDC 2 5W plus 1 25 W per additional I O module See page 6 for Power Supply options Recommended Fuse External Edison S5061 R Time Delay 1A Fuse Communications 4 Integrated Ports USB IN Programmin...

Страница 2: ...H MIN MAX P1 08TD1 Check all latches are secure after modules are connected CPU Front Panel P1 540 RUN STOP PWR RUN CPU REMOTE I O RS 232 RS 485 10 100 ETHERNET ACT LINK G T LINK ACT PGM LINK RX TX TX...

Страница 3: ...compartment located on the top of the CPU Step Two Insert battery and close compartment Squeeze tabs and pull battery holder up to remove battery P1 540 P1 540 Take care to insert battery behind tab...

Страница 4: ...Maximum 3 RXD RS 232 Input 4 TXD RS 232 Output 5 RTS RS 232 Output 6 GND Logic Ground RS 485 Port Specifications Port Name RS 485 Description Non isolated RS 485 port connects the CPU as a Modbus ASC...

Страница 5: ...RD 1 2 3 4 5 6 7 8 TD TD RD RD 1 2 3 4 5 6 7 8 TD TD RD RD 1 2 3 4 5 6 7 8 RJ45 RJ45 RJ45 RJ45 OR WHT OR GRN WHT BLU BLU WHT GRN BRN WHT BRN OR WHT OR GRN WHT BLU BLU WHT GRN BRN WHT BRN OR WHT OR GRN...

Страница 6: ...Conductor 28 16 AWG Stranded Conductor Screw Driver Width 1 8 in 3 175 mm Maximum Screw Size M2 Screw Torque 1 7 lb in 0 4 N m Productivity1000 Power Supplies All Productivity1000 PLC CPUs require 24...

Страница 7: ...7 Sales 800 633 0405 www productivity1000 com...

Страница 8: ...al codes that regulate the installation and operation of your equipment These codes vary from area to area and it is your responsibility to determine which codes should be followed and to verify that...

Отзывы: