CTRINTR Example (cont’d)
Rung 2: This rung is a sample method for enabling the CTRINTR command. A C-bit is
used to allow the programmer to control the command from Data View for testing purposes.
Turning on C0 will cause the CTRINTR instruction to create a single entry preset table, but
not as a file, and use it for output #0, the new preset will be loaded when the current count is
reset. In this case the single preset will be a set at a count of 25 for output #0.
Operating procedure for this example code is to load the CTRINTR_ex1.cwb file to your
CTRIO, then enter the code shown here, change to RUN mode, enable output #0 by turning
on C2 in Data View, turn encoder on CTRIO to value above 10 and output #0 light will
come on. Now turn on C0 to execute the CTRINTR command, reset the counter with C1,
then turn encoder to value of 25+ (output #0 should turn on).