21
pressing the
UP
key again will add the currently displayed value to the previously stored tare
value resulting in a new stored tare value. To reset the tare value to zero, press the
UP
key for 3
seconds. The
TARE
Led will turn off and the displayed value will be the gross value (without
the tare).
tare 2
To configure the meter for Tare 2 mode, select
tArE2
under the
ModtA
menu in Display
Configuration
CndSP
. After saving the Tare 2 mode configuration and returning to
RUN
mode, pressing the UP key for 3 seconds will allow access to manually enter and store a tare
value. After the tare value has been manually entered and saved, the meter returns to
RUN
mode,
TARE
Led will light and from this point the value displayed on the meter is the net
value, i.e., the measured value minus the stored tare value. To reset the tare value to zero, press
the
UP
key for 3 seconds and manually enter and store a new tare value of zero. The
TARE
Led
will turn off and the displayed value will be the measured value (without the tare value applied).
tare 3
To configure the meter for Tare 3 mode, select
tArE3
under the
ModtA
menu in Display
Configuration
CndSP
. After saving the Tare 3 mode configuration and returning to
RUN
mode, pressing the
UP
key for 3 seconds will allow access to manually enter and store a tare
value. After the tare value has been manually entered and saved the meter returns to
RUN
mode
but the stored value is not yet applied to the displayed value. To apply the stored tare value press
the
UP
key, the
TARE
Led will light and from this point the value displayed on the meter is
the measured value plus the stored tare value. To reset the tare value to zero, press the
UP
key
for 3 seconds and manually enter and store a new tare value of zero or enter the Configuration
Display
CndSP
/
ModtA
menu and reselect tare3. Upon returning to
RUN
, the
TARE
Led
will turn off and the displayed value will be the measured value (without the tare value applied).
Process to manually enter a
tare value in Tare 2 or Tare
3 modes
3s
±
.