5
FEATURES
Thank you for purchasing the ATA
EasyRoller Automatic Garage Door
Opener. This opener is designed to suit
vertical operating continuous curtain
roll up doors. The components and
materials used in this opener are of the
latest technology and highest quality.
Listed below are some of the many
features.
OPERATION
To open or close the door simply press
the hand held transmitter, the wall
mounted transmitter, or optional wall
switch for two seconds. During an open
or close cycle the door can be stopped
by pressing the button while the door is
in motion. The next actuation will move
the door in the opposite direction.
HOPPING CODE
Every time a transmission is made from
the
remote
transmitter a new security
code is generated. The number of
possible code combinations is over 4.29
billion. This greatly enhances the
security of the system. Code “grabbing”
is made a thing of the past.
SECURITY CODE STORE
The EasyRoller Garage Door Opener
uses state of the art technology in
storing your selected transmitter
security code. Up to eight different
transmitters can be stored in the openers
memory.
WEATHERPROOF DESIGN
The opener’s control board is housed in
a weather-proof enclosure rated to IP24.
This offers protection from rain
however the unit should not be sprayed
by a hose or any other water carrying
device.
ALPS (AUTOMATIC LIMITS
POSITIONING SYSTEM)
The ALPS system automatically
calculates the doors’ travel limits and
stores it in memory. If the door is
moved manually within the travel limits
during a power failure, the ALPS will
recognise this once the power is
restored and stop at the correct limit
position if the door is activated.
During installation the hand held
transmitter can be programmed to set
the door limits positions.
ISS (INTELLIGENT SAFETY
OBSTRUCTION SYSTEM)
While the door is performing a close
cycle, should it hit an obstacle or be
restricted in some manner, it will
automatically reverse. The amount of
force the door should encounter before
reversing is automatically adjusted by
the doors control system during the
initialisation of the automatic door
opener. The door will also stop if
restricted whilst opening. The Safety
Obstruction Force should be checked at
least once a month. See installation
manual for instructions.
LOCKABLE CONTROL PANEL
The control panel can be locked and
disabled to prevent tampering. This is
useful if the opener is to be mounted on
an exposed carport or a perimeter door.
Locking the control panel will prevent
operating the door via the Operate
button, re profiling, clearing limits,
clearing transmitters, changing force
margins, and coding transmitters.
OVER LOAD INDICATOR
When the maximum opening and
closing capacity of the opener is
exceeded an audible beeper will sound
to indicate that an overload has
occurred.
PHOTO ELECTRIC BEAM
(OPTIONAL)
The opener has an input for a photo
electric beam to be connected for extra
safety protection and use of the auto
close mode.
MANUAL OPERATION
The opener is equipped with a unique
patented manual disengaging device. If
the power to the opener is disrupted for
any reason the door can be put into
manual mode by pulling down on the
string handle, then releasing. This will
allow you to manually open or close the
door. When power is restored, by
pulling down on the string handle and
releasing, the opener is put back into
automatic mode.
SECURITY LOCK FOR MANUAL
RELEASE HANDLE (OPTIONAL)
For added security the manual release
handle can be locked out or disabled.
This is ideal if the opener is to be
mounted on a perimeter door in an
exposed carport.