OPERATING CONTROLS

PROG INPUT

is used for the

connection of the ATA Universal
Programmer for the purpose of
editing control and receiver
functions.

P. E. SHUNT. 

The shunt has to be

removed when connecting a Photo
Electric Beam.

NOTE: P.E. SHUNT

must not be

removed otherwise the opener will
not function correctly. Remove
only when a P.E beam is to be 
connected.

STATUS LED 

(Yellow) indicates

when the datum adjustment screw
has reached correct position.

DATUM ADJUST SCREW

Used to set mid point of door trav-
el during limits set up.

DOOR CODE button 

(blue) is

used for storing or erasing the
transmitter button you wish to use
to command the door to open, stop
or close.

CODING

LED 

(red) light 

indicates whether a code is being
stored or when a transmitter button
is pressed.

SET button 

(orange) is used

during the installation phase
together with the Plus and Minus
buttons to set the door limit 
positions. The Set button is also
used to re-initialise the Opener.

1.

2.

3.

4.

5.

6.

7.

OPERATE button 

(blue) is used

during installation to test the open,
stop and close cycles for the 
opener. The opener has to be 
initialised by the Set button before
the OPERATE button becomes
operable.

FORCE MARGIN SET

The

obstruction force pressure is set 
automatically by the opener during 
installation. The pressure can be 
adjusted manually using the Force
Margin Set button (White).
Pressing the force margin set 
button and open or close button
will increase or decrease the
amount of force. The Force Margin
Set is only ever used if other
environmental factors (wind, etc.) 
affect the operations of the
door/opener.

PLUS button 

(green) can be used 

during installation to set the open
limit position. Pressing this button
will move the door in the open
direction. Movement stops when
the button is released.

NOTE: The open safety 
obstruction detection is 
inoperable whenever the Close
Drive button is used to move
door. This button is disabled
after initialisation.

This button is also used to increase
the force margin sensitivity.

8.

9.

10.

OPEN LIMIT LED 

(green) the

led is very helpful during 
installation. It illuminates and
flashes when the door is opening
and remains steady on when the
open limit position has been
reached.

MINUS button 

(red) can be used 

during installation to set the close
limit position. Pressing this button
will move the door in the close
direction. Movement stops when
the button is released.

NOTE: The close safety 
obstruction detection is 
inoperable whenever the Close
Drive button is used to move
door. This button is disabled
after initialisation.

This button is also used to decrease
the force margin sensitivity.

CLOSE LIMIT LED 

(red) the led

is very helpful during installation.
It illuminates and flashes when the
door is closing and remains steady
on when the close limit position
has been reached.

ENGAGE/DISENGAGEMENT
CORD 

is used to switch the door

into manual mode especially in
case of a power failure.  The length
of the string is also adjustable.

SECURITY

LOCK FOR 

MANUAL RELEASE

(where 

fitted) prevents the manual release
handle being pulled to disengage
the opener into manual mode.

11.

12.

13.

14.

15.

Содержание GDO-8 v1 EasyRoller II

Страница 1: ...ation Instructions WARNING It is vital for the safety of persons to follow all instructions Failure to comply with the installation instructions and the safety warnings may result in serious personal...

Страница 2: ......

Страница 3: ...al Specifications Trouble Shooting Guide Parts List Warranty 4 5 6 8 9 9 9 10 11 11 12 13 13 14 14 14 15 15 15 16 16 16 17 17 18 19 20 Automatic Technology Australia Pty Ltd to the extent that such ma...

Страница 4: ...ll times Warning It is vital for the safety of persons to follow all instructions Failure to comply with the following Safety Rules may result in serious personal injury and or property damage The uni...

Страница 5: ...held transmitter can be programmed to set the door limits positions ISS INTELLIGENT SAFETY OBSTRUCTION SYSTEM While the door is performing a close cycle should it hit an obstacle or be restricted in...

Страница 6: ...ount of force The Force Margin Set is only ever used if other environmental factors wind etc affect the operations of the door opener PLUS button green can be used during installation to set the open...

Страница 7: ...CODING LED RED 7 SET BUTTON ORANGE 8 OPERATE BUTTON BLUE 9 FORCE MARGIN SET BUTTON 10 PLUS BUTTON FOR LIMITS SETTING FORCE MARGIN 11 OPEN LIMIT LED GREEN 12 MINUS BUTTON FOR LIMITS SETTING FORCE MARG...

Страница 8: ...TER PTX 4 1 ALKALINE BATTERY A23 12V 1 WEIGHT BAR NOT INCLUDED IN SOME MODELS 1 PAN HEAD SCREW M4x50mm NOT INCLUDED IN SOME MODELS 2 NILOCK HEX NUT M4 NOT INCLUDED IN SOME MODELS 2 FLAT WASHER I D 3 1...

Страница 9: ...ould not stick or bind in the guide tracks The ideal operational effort in raising or lowering the door should not exceed a force of 10kg 22 lbs Make sure that all door locks ropes chains etc are eith...

Страница 10: ...upported remove the right hand door mounting bracket from wall 6 Remove the drive assembly from the packaging Try to rotate the drive gear by pushing on the fork If the gear does not rotate the manual...

Страница 11: ...e set 6 1 CODING TRANSMITTER FOR SETTING LIMITS 1 Press and hold the Door Code button Fig 9 2 Press button 1 Fig 11 on the transmitter for two seconds 3 Release and pause for two seconds 4 Press the s...

Страница 12: ...oor to your desired closed position IMPORTANT WARNING Please be aware that the garage door will start closing automatically once step 8 is performed The door will also automatically re open after full...

Страница 13: ...SSURE 1 Press and hold the Force Margin Set button Fig 12 2 While holding down the Force Margin button press the Plus button Each press increases the force margin in both directions The Open Limit LED...

Страница 14: ...er to see if it operates the door 11 DELETING PROGRAMMED CODES 11 1 DELETING A STORED TRANSMITTER CODE 1 Select the transmitter you want to delete 2 Press and hold the Door Code button Fig 14 3 Press...

Страница 15: ...tion Fig 18 Note The door may move uncontrollably if the spring tension is weak or not set properly or the door is unbalanced If this occurs do not use the door and contact your installer for service...

Страница 16: ...tion force margin setting Force Margin Set Minus Decreases the obstruction force margin setting Force Margin Set then Set Reloads the factory set default obstruction force margin setting Close for 6 S...

Страница 17: ...NATIONS Over 4 29 Billion Random Codes CODE GENERATION Non linear Encryption Algorithm PTX 4 TRANSMITTER BATTERY A23 Alkaline 12 Volts DEFAULT SETTINGS AND SPECIFICATIONS 17 Note 1 The maximum continu...

Страница 18: ...the tracks Possible obstruction in the doorway Increase force margin setting See Step 8 3 on page 13 Or re calculate force margin See Step 8 6 on page 13 Remove obstruction Door operates from drive un...

Страница 19: ...APTITE SCREW P M4X10 PAN HEAD SCREW W WASHER M4X8 TAPTITE SCREW P BLACK ZNC M3X14 INTERNAL TOOTH LOCK WASHER I D 3 CABLE TIE 4 GT 100M STRING HANDLE ASSY CONTROL BOARD CB 17 CHASSIS ENCLOSURE ASSY CHA...

Страница 20: ...complete modification or repairs to the product carried out by a person who is not authorised or has not been trained by ATA to carry out such modification or repairs n faulty or unsuitable wiring of...

Отзывы: