background image

SELF INSTALL - NEED TECHNICAL

ASSISTANCE?

OPTION 1: DIRECT WITH THE SERVICE DESK QUICKEST AND MOST EFFECTIVE METHOD

Submit your enquiry direct with the service desk at

[email protected]

The service desk has the most experienced staff in Australia to help with your problem but they need your help.

Describe your problem in detail and as clearly as possible. Don t forget to include a telephone number.

Be certain to detail which model or models of you are working with.

Send photos of the installation they love photos. The people at the service desk are good but they are

even better when they can see the installation. Send photos of the overall scene so they can see the

entire installation. Also send photos of the wiring to the control board and any other part of the

installation you think is relevant.

Send video if appropriate. Smartphone s these days take remarkably good video in small file sizes which

can be emailed in a moment. If your problem needs a video to show the issue please feel free to send it.

NOTE: THIS IS BY FAR THE FASTEST AND MOST SUCCESFUL WAY TO SOLVE YOUR PROBLEM

PHOTOS AND VIDEOS ARE THE NEXT BEST THING TO BEING THERE

OPTION 2: LODGE YOUR ENQUIRY LOCALLY - SLOWER BUT CAN STILL BE EFFECTIVE

Make contact with the store of purchase. Branch staffs are typically not technicians and dependent on their length

of service will have varying degrees of technical knowledge. If they cannot help however they will certainly either

source help locally from their technicians or make contact with the service technicians on your behalf.

OPTION 3: SERVICE CALL WITH AUTOMATIC SOLUTIONS TECHNICIAN SLOWEST METHOD

If you fall within the local branch service area it may be possible to book a local technician to look at your

installation. Wait times will vary dependent on local workloads. The cost is a service fee which includes the first

half hour and the hourly rate thereafter. If any Automatic Solutions provided parts are found to be defective and

within warranty these will be provided free of charge.

(NOTE: If you suspect that any parts are defective and within warranty you may wish to consider option 4)

A note on this option: If you decide on this option you will be asked to sign an  authorisation to proceed  which

will provide legal authority and payment security. This form has three options available of which only the first two

are available to you. The third option is for warranty repairs only for full install customers. Self install customers

requiring warranty only service need to refer to option four below.

IMPORTANT: IN SHORT THIS OPTION WILL INCUR CHAR

GES

OPTION 4: RETURN THE PRODUCT IF BELIEVED TO BE FAULTY

As a self install customer who has purchased product if you believe the product to be faulty rather than an

installation or site problem you have the option of returning the product for evaluation and to exercise your right

to a replacement, repair or refund as applicable. All returned product is forwarded immediately to the service

technicians for evaluation and response. There are two main methods available to return product

Direct to the service centre this is the quickest method as it cuts out the branch delay

Via the branch of purchase slower because of the delay at the branch

When choosing this option you need to complete a product return form. This form gives you all the information

on procedure involved and where to send to.  These are available at the branch of purchase, can be emailed to

you (contact your branch), or available here -

http://automaticsolutions.com.au/page/warranty.php

Содержание 750L I Range

Страница 1: ... components Installation and Maintenance Manual Sliding Gate Operators Inbuilt Models ASA 550L I 750L I Range Made in Australia from Australian quality imported components April 2010 N14870 Installation and Maintenance Manual Sliding Gate Operators Inbuilt Models ASA 550L I 750L I Range Made in Australia from Australian quality imported components ...

Страница 2: ...the gate frame keeping 1mm 2mm clearance between the rack teeth and Pinion wheel Once the rack is fixed move the gate and sight the rack moving over the pinion wheel check that most of the pinion wheel meshes with the rack Make sure rack runs freely over the pinion wheel any tights spots should be corrected by adjusting the rack height Check the operator is firmly bolted down to the concrete pad E...

Страница 3: ...he gate travels is in accordance with the opening and closing status LED s if not reverse two of the motor wires at the inverter terminals Inverter settings can be adjusted via the keypad i e Opening speed closing speed and ramp times Automation settings operating modes are able to be adjusted via the CB6 board refer to manual for further instructions Once Inverter settings are appropriately set p...

Страница 4: ...tion 3 Installation Page 6 10 Electrical Cabling Mechanical Installation Electrical Connections CB6 Control Board Variable Speed Drive Unit Commissioning Section 4 Manual Release Instructions Page 10 Section 5 Maintenance Page 11 Section 6 Warranty Page 12 Annexure Control Board Layout for Inverter Controls Schematic Wiring Diagram ...

Страница 5: ... install the automation equ ically to open and close sliding gates or doors and sh read through this installation manual ols are in new condition and have not been damaged i ociated support posts and walls to protect against shea aps which could cause serious injury or death Take in nding environment structure has the necessary strength and rigidity to su ng and closing gate motion riate Photo Ele...

Страница 6: ...g the previous sections in this manual and having checked for suitable installation proceed as follows Electrical Cabling A suitably rated Isolator and 240v power supply should be available near to where the gate operator is to be mounted The following diagrams will provide measurements for the positioning of conduits and the appropriate position for mounting the operator whether a GDS 550 450LI o...

Страница 7: ... and operator in approximate mounting location Use the rack to locate the operator the correct distance away from the gate rail finer adjustment can be made after Dynabolt or chemical anchor the bottom mounting plate to the concrete mounting pad using 12 x 100mm fixings Unscrew anticlockwise the manual disconnect knurled knob so the drive gear free wheels Fix the rack to the gate rail ensuring the...

Страница 8: ...ng associated with it use an IM 1 module to isolate it from the control board s input The IM 1 is available from the manufacturer Powering Accessories Accessories which require a 24v AC supply can be powered from the transformer output used to power the control board via the isolated 24v AC supply which is connected to the DIN rail terminals as labelled However the transformer s current capacity m...

Страница 9: ...inal will only open the door gate The input also resets the P E triggered auto close mode so that the P E input will need to be triggered again before a P E auto close cycle will be initiated Position 5 M 2 OUTPUTS STATUS OFF The M2 output controls second motor ON The M2 output controls status lights Position 6 P E STOPS CLOSE CYCLE OFF Activating the P E input while motors are closing causes the ...

Страница 10: ...ing times Note when setting the OPEN and CLOSE cycle times when limit switches are used release the push button a few seconds after the limit switch cuts motor power This allows for the motors to slow down over the life of the operators without the need to adjust again Variable Speed Drive Unit The variable speed drive unit will ramp up the speed of the operator and then ramp down prior to closing...

Страница 11: ...nversely not too late so the torque limiter is operating Tighten torque limiter knurled knob Set open closed travel time Check that all safety devices work as designed and the electromagnetic lock holds the gate firmly closed if fitted Install cover using screws provided in the front and sides to hold cover firm Provide full details to the owner concerning the operation and relevant maintenance an...

Страница 12: ...ical connections tig Limit Switches operate in ap External safety devices work Electromagnetic lock if fitte Gearbox self locking i e sea General operation i e speed Comments Service performed by S ult in injury or death and or damage to property and eq formed on the operator and gate are as follows cycles a day each month 100 150 cycles a day every 2 month 50 99 cycles a day every 4 months 20 49 ...

Страница 13: ... in the following circumstances i If no proof of date of purchase can be produced ii If the product has been used in a manner beyond its design parameters iii If the product is tampered with or repaired by personnel not authorised to do so iv In respect of loss or damage caused by rough treatment v If the product is not used and maintained in accordance with instructions or recommendations listed ...

Страница 14: ...Single Controls Dual Controls ...

Страница 15: ...7 Motor 2 Limit Switch Inputs no t shown 8 Terminals for Isolated 24vAC Supply 21 Firmware Version Label for Limit Switch and Control Inputs 22 Light Control Relay Interface 9 Pedestrian Access Control Input Connector 10 Open Stop Close Control Input 23 Inp ut Status L E Ds 11 Close Control Input 24 Stop Input Jumper 12 Stop Control Input 25 Open Input Jumper 13 Open Control Input 26 PE Beam Input...

Страница 16: ...service area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local workloads The cost is a service fee which includes the first half hour and the hourly rate thereafter If any Automatic Solutions provided parts are found to be defective and within warranty these will be provided free of charge NOTE If you suspect that any parts are defec...

Отзывы: