background image

M

ODE

S

ELECTION

Using the mode selection dip-switches select the desired operating modes. Note the times associated with
the parameters marked with an * can be changed. The auto-close times can be changed using the procedure
in the following section. See the instruction manual for details on how to change the other parameters.
See the detailed instruction manual for details on how to change the other parameters.

Position 1

SYNCHRONISING DELAY

OFF - No delay
ON -

Motor 1 starts to open 2 seconds* before Motor 2 and Motor 2 starts to close 2 seconds* before
Motor 1.

Position 2

PULSE LOCK OUTPUT

OFF - Lock output is activated for the entire motor drive cycle.
ON -

Lock output pulses for 0.3 seconds* at the start of each drive cycle.

Position 3

LIGHT OUTPUTS WARNING

OFF - Optional light module controls a light with timer which turns light off after 60seconds*.
ON -

Optional light module controls a warning light which activates whenever motors are on.

Position 4

SWIPE MODE (OSC INPUT)

OFF - OSC input terminal has standard Open, Close, Stop action.
ON -

OSC input terminal will only open the door/gate. The input also resets the P.E triggered

auto-close mode so that the P.E input will need to be triggered again before a P.E auto-
close cycle will be initiated.

Position 5

M 2 OUTPUTS STATUS

OFF - The M2 output controls second motor
ON -

The M2 output controls status lights

Position 6

P.E STOPS CLOSE CYCLE

OFF - Activating the P.E input while motors are closing causes the motors to reverse.
ON -

Activating the P.E input while motors are closing causes the motors to stop but not reverse.

Position 7

P.E STOPS OPEN CYCLE

OFF - Activating the P.E input while motors are opening is ignored by the controller.
ON -

Activating the P.E input while motors are opening causes the motors to stop.

Position 8

P.E TRIGGERED AUTO-CLS

OFF - Not selected
ON -

Selects the P.E triggered auto-close mode which causes the motors to auto-close if

the P.E input is activated then released. (Auto-close delay time is 0 seconds*)

Position 9

PEDESTRIAN AUTO-CLS

OFF - No pedestrian access auto-close
ON -

Selects auto-close in the pedestrian access mode. (Auto-close delay time is 15

seconds*)

Position 10

STANDARD AUTO-CLS

OFF - Not selected
ON -

Selects standard auto-close mode which will close the motors after fully opening.

(Auto-close delay time is 30 seconds*)

Содержание 750L I Range

Страница 1: ... components Installation and Maintenance Manual Sliding Gate Operators Inbuilt Models ASA 550L I 750L I Range Made in Australia from Australian quality imported components April 2010 N14870 Installation and Maintenance Manual Sliding Gate Operators Inbuilt Models ASA 550L I 750L I Range Made in Australia from Australian quality imported components ...

Страница 2: ...the gate frame keeping 1mm 2mm clearance between the rack teeth and Pinion wheel Once the rack is fixed move the gate and sight the rack moving over the pinion wheel check that most of the pinion wheel meshes with the rack Make sure rack runs freely over the pinion wheel any tights spots should be corrected by adjusting the rack height Check the operator is firmly bolted down to the concrete pad E...

Страница 3: ...he gate travels is in accordance with the opening and closing status LED s if not reverse two of the motor wires at the inverter terminals Inverter settings can be adjusted via the keypad i e Opening speed closing speed and ramp times Automation settings operating modes are able to be adjusted via the CB6 board refer to manual for further instructions Once Inverter settings are appropriately set p...

Страница 4: ...tion 3 Installation Page 6 10 Electrical Cabling Mechanical Installation Electrical Connections CB6 Control Board Variable Speed Drive Unit Commissioning Section 4 Manual Release Instructions Page 10 Section 5 Maintenance Page 11 Section 6 Warranty Page 12 Annexure Control Board Layout for Inverter Controls Schematic Wiring Diagram ...

Страница 5: ... install the automation equ ically to open and close sliding gates or doors and sh read through this installation manual ols are in new condition and have not been damaged i ociated support posts and walls to protect against shea aps which could cause serious injury or death Take in nding environment structure has the necessary strength and rigidity to su ng and closing gate motion riate Photo Ele...

Страница 6: ...g the previous sections in this manual and having checked for suitable installation proceed as follows Electrical Cabling A suitably rated Isolator and 240v power supply should be available near to where the gate operator is to be mounted The following diagrams will provide measurements for the positioning of conduits and the appropriate position for mounting the operator whether a GDS 550 450LI o...

Страница 7: ... and operator in approximate mounting location Use the rack to locate the operator the correct distance away from the gate rail finer adjustment can be made after Dynabolt or chemical anchor the bottom mounting plate to the concrete mounting pad using 12 x 100mm fixings Unscrew anticlockwise the manual disconnect knurled knob so the drive gear free wheels Fix the rack to the gate rail ensuring the...

Страница 8: ...ng associated with it use an IM 1 module to isolate it from the control board s input The IM 1 is available from the manufacturer Powering Accessories Accessories which require a 24v AC supply can be powered from the transformer output used to power the control board via the isolated 24v AC supply which is connected to the DIN rail terminals as labelled However the transformer s current capacity m...

Страница 9: ...inal will only open the door gate The input also resets the P E triggered auto close mode so that the P E input will need to be triggered again before a P E auto close cycle will be initiated Position 5 M 2 OUTPUTS STATUS OFF The M2 output controls second motor ON The M2 output controls status lights Position 6 P E STOPS CLOSE CYCLE OFF Activating the P E input while motors are closing causes the ...

Страница 10: ...ing times Note when setting the OPEN and CLOSE cycle times when limit switches are used release the push button a few seconds after the limit switch cuts motor power This allows for the motors to slow down over the life of the operators without the need to adjust again Variable Speed Drive Unit The variable speed drive unit will ramp up the speed of the operator and then ramp down prior to closing...

Страница 11: ...nversely not too late so the torque limiter is operating Tighten torque limiter knurled knob Set open closed travel time Check that all safety devices work as designed and the electromagnetic lock holds the gate firmly closed if fitted Install cover using screws provided in the front and sides to hold cover firm Provide full details to the owner concerning the operation and relevant maintenance an...

Страница 12: ...ical connections tig Limit Switches operate in ap External safety devices work Electromagnetic lock if fitte Gearbox self locking i e sea General operation i e speed Comments Service performed by S ult in injury or death and or damage to property and eq formed on the operator and gate are as follows cycles a day each month 100 150 cycles a day every 2 month 50 99 cycles a day every 4 months 20 49 ...

Страница 13: ... in the following circumstances i If no proof of date of purchase can be produced ii If the product has been used in a manner beyond its design parameters iii If the product is tampered with or repaired by personnel not authorised to do so iv In respect of loss or damage caused by rough treatment v If the product is not used and maintained in accordance with instructions or recommendations listed ...

Страница 14: ...Single Controls Dual Controls ...

Страница 15: ...7 Motor 2 Limit Switch Inputs no t shown 8 Terminals for Isolated 24vAC Supply 21 Firmware Version Label for Limit Switch and Control Inputs 22 Light Control Relay Interface 9 Pedestrian Access Control Input Connector 10 Open Stop Close Control Input 23 Inp ut Status L E Ds 11 Close Control Input 24 Stop Input Jumper 12 Stop Control Input 25 Open Input Jumper 13 Open Control Input 26 PE Beam Input...

Страница 16: ...service area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local workloads The cost is a service fee which includes the first half hour and the hourly rate thereafter If any Automatic Solutions provided parts are found to be defective and within warranty these will be provided free of charge NOTE If you suspect that any parts are defec...

Отзывы: