background image

2

Table of contents

1 -  SYMBOLS USED IN THE MANUAL

Pay special attention when reading this manual to the parts marked by the symbols:  

NOTE!
Suggestions for the user

ATTENTION!
Possible hazardous situation 
for the product and the environment

DANGER!
Serious danger for 
personal safety and life

2 -  APPROPRIATE USE OF APPLIANCE

The FIREX 

appliance has been built according to the current level of engineering and acknowledged 

technical safety rules.

 

Nonetheless, if improperly used, dangers could arise for the safety and life of the user and other persons 
or damage to the equipment or other objects. 
The appliance is intended to operate in hot air circulation heating systems. Any other use must be considered 
improper. 
Firex shall not be held liable for any damage resulting from improper use; in this case the user is fully 
responsible for the risk. 
Use according to the intended purposes also includes careful compliance with the instructions in this manual.

3 -  WATER TREATMENT

•  The hardness of the feed water conditions the frequency at which the domestic hot water producer must be 

cleaned.

•  If the water has a hardness greater than 15°f, we recommend using water softeners, chosen according to the 

characteristics of the water.

•  We recommend checking and cleaning any installed domestic hot water exchanger at the end of the fi rst 

year of use and every two years thereafter; on this occasion, also check the state of wear of the anode.

TABLE OF CONTENTS

1  Symbols used in the manual ..................................................................................................................................................... 2
2  Appropriate use of appliance ................................................................................................................................................... 2
3 Water 

treatment 

......................................................................................................................................................................... 2

4  Information provided to the user by installer/maintenance technician .................................................................................. 3
5 Safety 

warnings 

......................................................................................................................................................................... 3

6 Operating 

instructions............................................................................................................................................................... 4

6.1  Standard panel board ......................................................................................................................................................... 4
6.2  Checks before commissioning .......................................................................................................................................... 6
6.3 The wood ............................................................................................................................................................................ 7
6.4 Wood humidity 

.................................................................................................................................................................... 7

6.5 Dimensions ......................................................................................................................................................................... 7
6.6 Start-up ............................................................................................................................................................................... 7
6.7  Combustion air adjustment ................................................................................................................................................ 8
6.8  Checks to be carried out after commissioning ................................................................................................................. 9
6.9 General warnings 

.............................................................................................................................................................. 10

6.10  Summer mode ................................................................................................................................................................ 10
6.11  Maintenance ................................................................................................................................................................... 11
6.12  Troubleshooting .............................................................................................................................................................. 12

Содержание Firex 34

Страница 1: ...Biomass Wood Fired Water Heaters Operating Manual Firex34 55kW ...

Страница 2: ...purposes also includes careful compliance with the instructions in this manual 3 WATER TREATMENT The hardness of the feed water conditions the frequency at which the domestic hot water producer must be cleaned If the water has a hardness greater than 15 f we recommend using water softeners chosen according to the characteristics of the water We recommend checking and cleaning any installed domesti...

Страница 3: ...LLATION MAINTENANCE TECHNICIAN 5 SAFETY WARNINGS ATTENTION The appliance must be installed adjusted and maintained by professionally qualified personnel in compliance with standards and provisions in force Incorrect installation can cause damage to persons animals and objects for which the manufacturer cannot be held responsible DANGER NEVER attempt performing maintenance or repairs on the boiler ...

Страница 4: ...t off With the switch at the boiler is powered electrically green indicator light on and is set up for operation The recirculation pump works Operating mode selection keys Using switch 13 it is possible to power off the system pump boiler load With the switch on 0 the system pump is not powered electrically When the switch is on the system pump is not electrically powered 32Working thermostat 41Ge...

Страница 5: ...imum temperature approx 65 C within the required amount of time the fan and recirculation pump will switch off The panel is powered but the boiler is not running Light the wood once again Heating temperature control It is possible to control the temperature of the FIREX boiler system water by turning the knob pos 32 clockwise to raise it and counter clockwise to lower it Temperature is adjusted be...

Страница 6: ...normally closed when the loading door is closed Opening the loading door causes the fan to start up automatically In this way the smoke accumulated in the wood storage is suctioned and sent to the chimney directly The bypass in conclusion allows the smoke to be discharged to the chimney without escaping from the loading door when loading the wood or during lighting Complete decommissioning When th...

Страница 7: ... together with the moisture content contribute to determine the boiler s output Small pieces with a length however conforming to indications indicated hereby are more easily flammable and therefore have the tendency to increase the boiler s output and therefore to reduce its autonomy Moreover they fall with greater facility in the lower chamber reducing the risk of the formation of bridges The so ...

Страница 8: ... LOADING Before loading wood once again consume the previous one as much as possible It can be reloaded when the bed of embers in the firewood compartment will be reduced to a thickness of about 5 cm Open the loading door and the internal anti smoke door slowly It is necessary to use wood logs with the length stated in the previous paragraph Place the new wood logs as described above USEFUL TIPS L...

Страница 9: ...G SEALS During the initial start up check the tightness of the smoke circuit and the connection to the chimney If there is any noticeable smoke leakage alert the installer and or our After Sales Service If there is any noticeable aspiration of air through the door seals tighten the handle with greater force Make sure the working thermostat is in good running order Te 32 at full power until it stop...

Страница 10: ...erefore necessary to install a mixer valve The corrosion caused by the flue gas condensation is not covered by the warranty as it is caused by the wood s moisture content and the way the boiler is used WARNINGS DURING USE Every time the air is adjusted wait 5 10 minutes before proceeding with the next adjustment When you have established the best air adjustment at the end of the day check the surf...

Страница 11: ...he firewood storage compartment Use the supplied brush to clean the triangular ducts in the furnace Remove the ashes contained in the smoke chamber from the side doors using a scraper Make sure that the slots in the grate are not obstructed if they are clear them up using the poker If the boiler continues to operate badly even after having cleaned it as described above the cause can be attributed ...

Страница 12: ...m When opening the loading door there are blowbacks and smoke escape Remedy Open slowly Use damper wood make sure that the boiler has not have prolonged downtime see chap 6 9 Use larger logs Consume the previous load of wood before reload ing Problem The boiler does not reach the requested temperature The flame is small and there is too much air Inspecting the wood storage the formation of log bri...