User operating instructions

6.11 - MAINTENANCE 

Danger!
Before performing any maintenance, 
make sure the boiler and its components 
have cooled down. 

 

Warnings 

Never drain water from the system, even partially, unless 
absolutely necessary.

Periodically check the proper operation and integrity of 
the fl ue gas exhaust pipe and/or device.

Do not clean the boiler and/or its parts with easily 
fl ammable substances (e.g. petrol, alcohol, etc.).
Do not leave fl ammable substances in the room where 
the boiler is installed.

Do not clean the boiler room while the boiler is running.

IMPORTANT

Use brushes and a vacuum cleaner to 
clean the heat stove; if rags are used, 
make sure they are all recovered.
Keep screws and nuts oiled and protect 
them with grease.

CLEANING AND ROUTINE MAINTENANCE OF 

THE WOOD-FUELLED BOILER

Every day

-  Remove the ashes from the lower cradle.
-  Shake down, with the scraper supplied with the boiler, 

the embers so that the ashes, accumulated in the fi re 
bed will fall down through the slots in the grate. This 
operation will help to avoid the grate from becoming 
obstructed and the subsequent bad operation of the 
boiler. This operation has to be done when the fl ame 
dies down, before loading wood.

Every week

-  Remove carefully all the residues of combustion 

accumulated in the fi rewood storage compartment.

-  Use the supplied brush to clean the triangular ducts 

in the furnace.

-  Remove the ashes contained in the smoke chamber 

from the side doors using a scraper.

-  Make sure that the slots in the grate are not 

obstructed: if they are, clear them up using the poker.

-  If the boiler continues to operate badly, even after 

having cleaned it as described above, the cause can 
be attributed to bad distribution of the secondary air.

In this case: 
1) check the adjustment of the air setting, according to 

the instructions given in the paragraph “Combustion 
air adjustment”.

2) make sure that the two secondary air supply holes 

that come through the grate are not obstructed: if 
they are, use a 

soft brush

 to clean out each duct.

Every month 

Check by-pass operation.
When the loading door is open the by-pass allows 
the fan to start up automatically, extracting the fl ue 
accumulated in the wood storage compartment, and 
sending it to the chimney.
The bypass, in conclusion, allows the smoke to be 
discharged to the chimney without escaping from the 
loading door when loading the wood or during lighting.

UNSCHEDULED MAINTENANCE OF WOOD-FUELLED 
BOILER

At the end of each heating season, perform a general 
cleaning of the boiler by removing all the ashes from 
the fi rewood storage compartment. 
During summer, keep the boiler doors closed.

Cleaning the fan

ATTENTION: 
This operation is reserved for qualifi ed 
personnel as incorrect maintenance 
could jeopardise operation of the boiler.

Содержание Firex 34

Страница 1: ...Biomass Wood Fired Water Heaters Operating Manual Firex34 55kW ...

Страница 2: ...purposes also includes careful compliance with the instructions in this manual 3 WATER TREATMENT The hardness of the feed water conditions the frequency at which the domestic hot water producer must be cleaned If the water has a hardness greater than 15 f we recommend using water softeners chosen according to the characteristics of the water We recommend checking and cleaning any installed domesti...

Страница 3: ...LLATION MAINTENANCE TECHNICIAN 5 SAFETY WARNINGS ATTENTION The appliance must be installed adjusted and maintained by professionally qualified personnel in compliance with standards and provisions in force Incorrect installation can cause damage to persons animals and objects for which the manufacturer cannot be held responsible DANGER NEVER attempt performing maintenance or repairs on the boiler ...

Страница 4: ...t off With the switch at the boiler is powered electrically green indicator light on and is set up for operation The recirculation pump works Operating mode selection keys Using switch 13 it is possible to power off the system pump boiler load With the switch on 0 the system pump is not powered electrically When the switch is on the system pump is not electrically powered 32Working thermostat 41Ge...

Страница 5: ...imum temperature approx 65 C within the required amount of time the fan and recirculation pump will switch off The panel is powered but the boiler is not running Light the wood once again Heating temperature control It is possible to control the temperature of the FIREX boiler system water by turning the knob pos 32 clockwise to raise it and counter clockwise to lower it Temperature is adjusted be...

Страница 6: ...normally closed when the loading door is closed Opening the loading door causes the fan to start up automatically In this way the smoke accumulated in the wood storage is suctioned and sent to the chimney directly The bypass in conclusion allows the smoke to be discharged to the chimney without escaping from the loading door when loading the wood or during lighting Complete decommissioning When th...

Страница 7: ... together with the moisture content contribute to determine the boiler s output Small pieces with a length however conforming to indications indicated hereby are more easily flammable and therefore have the tendency to increase the boiler s output and therefore to reduce its autonomy Moreover they fall with greater facility in the lower chamber reducing the risk of the formation of bridges The so ...

Страница 8: ... LOADING Before loading wood once again consume the previous one as much as possible It can be reloaded when the bed of embers in the firewood compartment will be reduced to a thickness of about 5 cm Open the loading door and the internal anti smoke door slowly It is necessary to use wood logs with the length stated in the previous paragraph Place the new wood logs as described above USEFUL TIPS L...

Страница 9: ...G SEALS During the initial start up check the tightness of the smoke circuit and the connection to the chimney If there is any noticeable smoke leakage alert the installer and or our After Sales Service If there is any noticeable aspiration of air through the door seals tighten the handle with greater force Make sure the working thermostat is in good running order Te 32 at full power until it stop...

Страница 10: ...erefore necessary to install a mixer valve The corrosion caused by the flue gas condensation is not covered by the warranty as it is caused by the wood s moisture content and the way the boiler is used WARNINGS DURING USE Every time the air is adjusted wait 5 10 minutes before proceeding with the next adjustment When you have established the best air adjustment at the end of the day check the surf...

Страница 11: ...he firewood storage compartment Use the supplied brush to clean the triangular ducts in the furnace Remove the ashes contained in the smoke chamber from the side doors using a scraper Make sure that the slots in the grate are not obstructed if they are clear them up using the poker If the boiler continues to operate badly even after having cleaned it as described above the cause can be attributed ...

Страница 12: ...m When opening the loading door there are blowbacks and smoke escape Remedy Open slowly Use damper wood make sure that the boiler has not have prolonged downtime see chap 6 9 Use larger logs Consume the previous load of wood before reload ing Problem The boiler does not reach the requested temperature The flame is small and there is too much air Inspecting the wood storage the formation of log bri...

Отзывы: