RAM™ 280-F Frozen Fry Dispenser
Copyright © 2011 Automated Equipment LLC All rights reserved.
20
Diagnostic Function Menu Structure
Diagnostic
Functions
Function Name
Description
D01
Exit Diagnostics
Immediate Return to Main screen.
D02
Display Last Error
Displays the last 10 recorded errors in reverse order starting
with the last error recorded.
Up button shows next error.
Down button shows previous error.
Enter button closes function.
D03
Error Log
Displays the number of occurrences of each error.
Display shows Error number and Number of Occurrences.
(i.e.: “
05 02
” means Error 5 has occurred 2 times since the
error log was last cleared.)
Up button shows next error.
Down button shows previous error.
Enter button closes function and returns to D01.
D04
Clear Errors
Clears the error log. Display will read “
Cl Err
”. Press enter
to continue. Display will Read “
Cl. No
”.
Up arrow will select ‘clear errors’.
Display will read “
Cl.YES
”
Press enter to clear error log and exit the function and
return to D1 or:
Down arrow will deselect ‘clear errors’.
Display will read “
Cl. No
”
Press the Enter button to execute selected option, exit the
function and return to D01.
D05
Calibrate Temperature
Probe.
Note
: See procedure
on
page 29
.
Caution: Read procedure on
page 29
before continuing.
Displays the cabinet temperature probe reading in tenths of a
degree i.e.”
-1.5°F
”
Allows the cabinet temperature probe to be corrected.
Up arrow will increase temperature in 0.1° increments.
Down arrow will decrease the temperature in 0.1°
increments.
Enter button will save the new setting and exit to D01.
D06
Read Control Probe*
*Used only with two
probe systems.
Displays the refrigeration temperature controller probe
reading in tenths of a degree i.e.”
-8.5°F
” . Displays “
---
“ on
single probe dispensers.
Note:
When two temperature probes are present, one is
mounted to an insulated block near the top wall of the cabinet
compartment in the upper right. This probe measures cabinet
temperature and is the temperature displayed on the front of
the operator panel. The other probe is below the block and
mounted against the back wall near the refrigeration
accumulator. This probe controls the refrigeration system.
Enter button will exit to D01.
D07
Control Probe Offset
Allows the temperature control probe to be offset to adjust for
any deviation from actual temperature and to allow for fine
tuning of the refrigeration cycle. Default is 0°F (0°C) for
single probe dispensers. Display will read “
oF. 0F
”. [Default
is 3°F (2°C) for two probe dispensers.] Adjustable from -5°F
to 15°F(-3°C to 8°C).
Up arrow will increase in 1° increments.
Down arrow will decrease in 1° increments.
Enter button will save the new setting and exit to D01