18
User Function Menu Structure
User
Functions
Function Name
Description
Main
Screen
Main Screen
Default condition of the display. Live temperature, error
display, and hopper status (full/empty)
U1
Last Basket/ Cancel
Selections
Halts weighing in process.
Turns off all size button lights.
Immediate return to Main screen.
U2
Calibrate Scales
Note:
See procedure
on
page 27
1. Request side to calibrate. Display reads: “
[CAL]
” with
alternating flashing brackets. Use Basket size button to
select side.
2. Waits for a basket to be placed for the side to be
calibrated then empties the accumulator doors into the
basket. The Display will read “
[ --
“ (“ -- ]”) until a basket
is presented.
3. Remove hopper for side to be calibrated. NOTE: Leave
the housing in place on the accumulator doors.
4. Tares automatically. Display reads “
[ 0.0
“ (“
0.0 ]”)
5. Waits for 1.0 lb reference. Display reads “
[ 1.0
“ (“ 1.0 ]”)
Place 1.0 lb (450 gr) weight on the accumulator doors.
6. Waits for 2.0 lb reference. Display reads “
[ 2.0
“ (“ 2.0 ]”)
Place 2.0 lb (900 gr) weight on the accumulator doors.
7. Waits for weight removal. Display will read “
---
“ Remove
weight(s) from the accumulator doors.
8. Reinstall
hopper.
9. The dispenser will return to normal operation with no
basket size selected on effected side.
U3
Enter Manager
Functions*
Request password (if set) to enter manager functions.*
Display shows dashes only if a password is set.
Goes straight to “
F1
” if no password is set. (
page 19
)
Use basket size buttons to enter five-digit password†.
Press the Enter Button to execute and close function.
If the password was successfully entered, “
F1
” will be
displayed. You are now in the Manager Menu. (
page 19
)
U4
Enter Diagnostic
Functions*
Request password, set or not, to enter diagnostic menu.
Display shows dashes only.
Use basket size buttons to enter five-digit password.
Note:
Password can be bypassed if not set. (press enter)
Enter button executes and closes function.
If the password was successfully entered, “
d01
” will be
displayed. You are now in the Diagnostics Menu. (
page 20
)
U5
Software version
Display shows current software version number. (i.e. “
1.0
“
Enter button closes function.
•
Use the Up
and Down
Arrow Buttons to find the desired function.
•
Press the Enter
Button to select the desired function.
•
Basket Size Buttons also function as numbers:
(Left Small=1, Left Medium=2, Left Large=3, Right Small=4, Right Medium=5, Right Large=6)
*Service Password to access both the Manager Menu and Diagnostic Menu: 22463†
†
Note: Using the Service Password to access the Manager Function menu will erase the
manager’s password (if set) and restore it to default (no password).