RAM™ 280-F Frozen Fry Dispenser
Copyright © 2011 Automated Equipment LLC All rights reserved.
17
Bypass Mode of Operation
Bypass mode will allow the one or both sides of
the dispenser to remain operational in the event
that a basket sensor fails. Bypass Mode is
intended to be a temporary condition until a
replacement basket sensor can be installed.
Note:
Bypass Mode is a volatile condition
and will return to normal operation if the
power is turned off and back on again.
While in Bypass Mode the effected sides basket
sensor is disabled and will not dispense fries
automatically into a basket when presented.
To dispense the fries into a basket, press the
selected Basket Size
Button after placing
an empty basket under the accumulator door
opening. The accumulator doors will cycle
each time the Basket Size
Button is
depressed.
While in Bypass Mode the dispenser will
otherwise appear to operate normally, refilling
the accumulator housings automatically after
each dispense cycle with the selected load of
fries.
Note
:
Engaging Bypass Mode (D11) is
performed from the Diagnostic Functions
Menu (
pages 20-22
) using the Operator
Panel on the front of the Dispenser and may
require a manager’s password to access the
menu.
To access the Diagnostics Menu, on the
Operator Panel, press the Up Arrow
button
until "
U4
" is displayed then press the Enter
button. The display will change to "
-----
" Enter
the managers password (if set) using the
basket size buttons. Then press the Enter
button.
Note: The Basket Size Buttons also function
as number buttons:
(e.g. the left medium basket button is
number 2, and the right large basket button
is number 6.)
The display will change to "
d01
". Press the Up
Arrow
button until "
d11
” is displayed then
press the Enter
button to access the
Bypass Basket Sensor Function.
The display will read “
[bYP]
” with alternating
flashing brackets. Use the Left or Right Basket
Size
Buttons to select the side to be
bypassed.
The display will default to the current sensor
condition.
Use the Up Arrow
Button to select bypass
mode for the effected side. The display will
read “
[YES
” if the left side is selected, (“ YES]”
if the right side is selected.) Press the Enter
Button to execute bypass mode and exit to
“
d01
”. Press Enter
again to exit the
diagnostics menu and enter bypass mode of
operation.
To deselect bypass mode for the effected side:
Press the Down Arrow
Button. The display
will read “
[ no
” if the left side is selected (“ no]”
if the right side is selected). Press the Enter
Button to exit the function and return to
“
d01
”. Press the Enter
Button again to
return to the main screen, or to return to normal
operation turn the power off for 15 seconds