41
Access the information from the Set up menu or from the installation warning screen.
Diagnostic messages help find an installation problem. The diagnostic messages are all
caused by external wiring, set up or installation issues which need fixing. They are not
caused by a fault with the AutoAnchor.
INTERNAL VOLTMETER/TEST TOOL:
This tool displays the voltages and status of
sensor, battery and load wires. The information is required by the AutoAnchor support
team for effective technical assistance.
Contact AutoAnchor support on:
www.autoanchor.co.nz/autoanchor-installation-help
Fill in the information form.
or
Email: [email protected] or Telephone: +64 9 360 300.
Press
again for extended diagnostic information and test tools.
PART 7 TECHNICIAN dIAGNOSTIC INFORMATION
Use
to scroll through the menus and to
Hold together to display the Set up menu.
The
must be turned off to access the Set up menu
.
Correct Parameters
AA Grey Sensor
Chain Only
Set Up
Bottom Fit Magnet
Polarity not relevant
Signal A -
(Red sensor wire from the console) is sensor power supply. Voltage
must be between 4.6V and 4.9V.
Signal B -
Reading depends on gap and magnet polarity.
Range 0.5V - 4.6V. Minimum working signal 0.5V.
Signal C -
I
f Signal B is less than 0.5V then Signal C will take over and
operate down to 100
mV
for an all chain set up.
AA Grey Sensor
Rope/Chain Set Up
Top Fit Magnet
Polarity not relevant
Signal A -
(Red sensor wire from the console) is sensor power supply.
Signal B -
Reading
is not relevant.
Signal C -
Minimum value is 100 mV when reading the chain pulses.
AA Black Sensor
Chain Only Set Up
Bottom Fit Magnet
South pole must face
sensor
Signal A -
(Red sensor wire from the console) moves between 2.6V and 4.6V.
Minimum working signal 0.5V.
Signal B -
Reading is not relevant
Signal C -
Reading is not relevant.
Reed Switch
Chain Only Set Up
Bottom Fit Magnet
Polarity not relevant
Signal A -
(Red sensor wire from the console) is not used.
Black sensor wire (from the console) is connected to the reed switch.
Signal B -
Range is 0.0V to 5V.
Signal C -
Reading is not relevant.
NPN Proximity
Sensor Chain Only
Set Up
Signal A -
(Red sensor wire from the console) is the proximity sensor’s power
supply.
Signal B -
Range 2.5V - 4.6V. Minimum working signal 0.5V
Signal C -
Reading is not relevant.
Sensor
Source
Icon
Signal
Voltage
(V)
Signal (mV)
To update the recorded signal levels rotate the windlass 2 or more turns
Press buttons or freewheel the windlass to rotate.
Check the windlass is safe and clear before using this function.
Sensor Information
Tuning done
Signal A 4.6 0.0
Signal B 2.5 0.5
Signal C -166 501
Sensor
Tuning done
Signal A 4.6 1.2
Signal B 5.0 0.0
Signal C -166 501
Sensor
Tuning done
Signal A 5.0 0.0
Signal B 0.0 5.0
Signal C -166 501
Sensor
Tuning done
Signal A 4.3 0.0
Signal C -166 501
Sensor
Tuning done
Signal A 4.6 0.0
Signal B 2.5 0.5
Signal C -166 501
Sensor
Tuning done
Signal A 4.6 0.0
Signal B 2.5 0.5
Signal C -166 501
Sensor
Signal B 0.5 3.5
3.5
2.2
AA
5
70
select windlass. Scroll to
"
Diagnostics
"
and select with