10-6
CARE OF YOUR MOTORHOME
12V TROUBLESHOOTING CHART (continued)
230V TROUBLESHOOTING CHART
Symptom
Cause
Remedy
230V system inoperative
No site power
Check site supply
RCD/MCB switches tripped out
Reset circuit breakers
RCD/MCB keeps tripping
Fault on 230V supply
Check supply including polarity
out
Faulty appliance
Turn off all appliances, reset
circuit breakers, turn on
appliances until fault occurs.
Isolate faulty appliance
Overload on current
10A maximum available do not
consumption by appliance
use appliance
Water heater does not
No power
Switch on isolator switch/
operate on 230V
check MCB is on
Overtemperature trip activated
Reset thermal cut-out (refer to
operating instructions)
Battery charger does not
Charger switched off
Switch on at control box/
operate
check MCB is on
Refrigerator does not operate
Switch on refrigerator
Check position of thermostat
on 230V
thermostat dial not ‘on’
dial
Element fault
Refer to dealer
Cooker Hotplate not heating
No power
Check MCB is on
up
Symptom
Cause
Remedy
Water Heater not
Fuse 11 blown
Find fault and replace fuse with
operating/cuts out
same rating
Low battery charge
Recharge battery
Unit fault
Refer to dealer
Cooker ignition not operating
Fuse 11 blown
Find fault and replace fuse with
same rating
Spark unit fault
Refer to dealer
Fault on cooker unit
Refer to dealer
Fridge gas ignition not
Fuse 11 blown
Find fault and replace fuse with
operating
same rating
Ignition control switch fault
Refer to dealer
Fridge ignition switch flashes
Fault on fridge unit
Refer to dealer
but gas does not ignite
Ignition can be heard to be
Faulty fridge ignition switch
Refer to dealer
sparking but no flashing on
fridge switch
Fridge does not operate on
Fuse 3 blown
Find fault and replace fuse with
12V when engine is running
same rating
Fuse 7 in EM50 interface
Find fault and replace fuse with
box blown
same rating
Fault on fridge relay
Refer to dealer
Fault on fridge unit
Refer to dealer
Содержание Peugeot Kemerton
Страница 2: ...DATA RECORD ...
Страница 10: ...2 4 MOTORHOME CODE ...
Страница 16: ...5 2 ARRIVAL AT SITE ...
Страница 24: ...6 8 SAFETY SECURITY ...
Страница 42: ...7 18 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Страница 69: ...9 23 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Страница 70: ...9 24 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Страница 75: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT ...
Страница 79: ...9 33 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY ...
Страница 80: ...9 34 FITTED EQUIPMENT DOUBLE BED ASSEMBLY ...
Страница 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2011 Ref 21210 ...