9-14
FITTED EQUIPMENT
TROUBLESHOOTING
The heater is equipped with an electronic diagnostic system which will detect fault conditions
ranging from poor gas or dc supply to internal heater malfunctions. In the event of a failure, the
red light on the control panel will flash a number of times, pause, and repeat until switched off.
Count the number of flashes and refer to the table below.
Check gas supply making sure there is gas in the bottle
and no blockage in the gas line. Ensure propane is used at
temperatures below +5
°
C. Clear lockout as described
below.
Check the air ducts and vents are not blocked or restricted.
We recommend you wait at least 5 to 10 minutes to allow th
heater to cool before clearing lockout as described below.
Minimum operating voltage is 10v, maximum is 15v, when
measured at the heater. Check battery voltage. If between
10v and 15v, check connections between heater and
battery. Check alternator or external battery charging. Clear
lockout as described below.
Attempt to clear lockout as shown below. If this fails,
contact a Whale Authorised Service Centre/Technician.
Number of
flashes
Fault
Remedy
No flame
detected
Overheat
Low/high
supply
voltage
Combustion
Air Fault
1
3
2
4
Check combustion air flue and exhaust flue for blockages.
5
Other/internal
fault
appliance should not normally require
cleaning. If it does, isolate the electrical
supplies and wipe down with a soft, damp
cloth only. Allow to fully dry before
reconnecting the electrical supplies.
The Whale Space Heater should be checked
periodically by a Whale Approved Service
Centre / Technician, or competent person, at
least annually. This should be completed
according to the practice in the country where
it is used and according to the Whale
instructions. We recommend annual testing
of gas soundness and combustion by an
accredited LPG gas engineer. The appliance
contains ESD sensitive components and
therefore should only be opened a Whale
Approved Service Centre / Technician.
Содержание Peugeot Kemerton
Страница 2: ...DATA RECORD ...
Страница 10: ...2 4 MOTORHOME CODE ...
Страница 16: ...5 2 ARRIVAL AT SITE ...
Страница 24: ...6 8 SAFETY SECURITY ...
Страница 42: ...7 18 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Страница 69: ...9 23 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Страница 70: ...9 24 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Страница 75: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT ...
Страница 79: ...9 33 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY ...
Страница 80: ...9 34 FITTED EQUIPMENT DOUBLE BED ASSEMBLY ...
Страница 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2011 Ref 21210 ...