59
2
1
Fig. 45:
Fastening screws or sensor
4) If an exhaust sensor is used, it will be fastened with the
M6x10 hexagon screw (2). Otherwise an M12x25
hexagon screw (1) is used instead of the sensor.
Fig. 46:
Placing the top storage brick
Only a certain quantity of storage bricks may be mounted.
How many bricks can be mounted depends on the exhaust
collar:
• Diameter 160/180 ->max 4 bricks
• Diameter 200/250 ->max 6 bricks
5) Placing the top storage brick on to the ring.
ð
The flue gas temperature beyond the rings must
not fall below 190°C!
1
Fig. 47:
Mounting threaded rod
6) The threaded rods (1) can be cut to the relevant
length with a saw before or after mounting.
ð
Please ENSURE when cutting that the thread turn is
not damaged.
ð
The length is dependent on the number of top
storage bricks.
1 brick - 240 mm
2 bricks - 360 mm
3 bricks - 480 mm
4 bricks - 600 mm
5 bricks - 720 mm
6 bricks - 840 mm
7) Screw the threaded rods (1) into the holes of the ring
at least 10x.