10 | Connection to ceramic flues
EN
Operating manual Folding corner fireplace inserts
44
10.2 Connection to metallic secondary heating surfaces
The specifications given in advance in respect of mounting instructions and installation regulations re-
main valid (see distances, thermal insulation, exhaust pipe connection).
The metallic heat exchanger can be placed to the left or right side or behind the fireplace insert.
For details, please see the following dimensioned sketch.
The base of the heat exchanger must be stable and heat resistant. The installation base on which the
heat exchanger is to be set up must be heat insulated in analogy to the manner described in the sec-
tion Protecting the installation floor.
Access to the cleaning openings on the heat exchanger must be ensured.
• General condition: The joining pieces from the fireplace insert and to the chimney must not longer
in total than 1 m.
Dimension A: 75 mm
Dimension B: 90 mm (insulation materials pursuant to AGI Q 132)
Dimension C: 50 mm
Mounting wall
Heat insulation
Inside edge cladding
Fig. 16:
Connection to ceramic flue heat exchanger