ELECTRICAL CONNECTION 

Before the electrical connection is made, the storage tank must be completely filled 
with water! 

 

CAUTION:  You  must  disconnect  the  power  before  any  intervention  in  the  water 
heater!

 

The electrical connection must be made according to the valid provisions and standards. 
The water heater is connected to the mains via the connection cable. 

 

In some cases, it is necessary to replace the installed connection cable with a new cable. 
To do this, the plastic casing of the water heater must be removed. In order to remove this, 
first remove the plate on the front of the casing by carefully inserting a spanner in the slot 
between the plate and protective cover, first at the thermostat knob and then opposite from 
the knob. If the plate is loosened on both sides, it can be removed by hand. Then remove 
the thermostat knob and remove the fastening screw below the knob. Last unscrew all four 
fastening screws and the casing can be removed. Now the installed connecting cable can 
be removed from the connecting terminal and replaced with a new cable.

 

 

It  should  be  noted  that  in  case  of  failure  (body  circuit  /  leakage)  it  can  trigger  the  RDC 
(Residual Current Device) come. This means that all electrical equipment is energized in 
this circuit.

 

Therefore, a separate RCD must be provided for the operation of the small memory should 
other  electrical  equipment  to  be  used,  in  which  an  uninterruptible  power  supply  must  be 
guaranteed, as Freezers, refrigerators for medicines, emergency lighting, etc.

 

 

 
Legend to symbols: 
1 - Thermostat 
2 - Heating fuse 
3 - Heating rod 
4 - Control lamp 
5 - Connecting terminal 
  
L - Phase conductor 
N - Neutral conductor 

 - Protective conductor 

 

 

 

 

 

 

 

Diagram for connection to the electrical line 

 

 
 
 

 

Содержание KRO

Страница 1: ...KRO KRU 5 10L...

Страница 2: ...2 INSTRUCTIONS FOR USE 3...

Страница 3: ...e impermissible A defective unit may not continue to be operated Installation and commissioning may only be performed by qualified specialised personnel who therefore assume the responsibility for pro...

Страница 4: ...water preparation within closed spaces and may only be installed with due consideration of the relevant professional standards The unit must be used exclusively in accordance with the conditions set...

Страница 5: ...ll screws with a nominal diameter of at least 5 mm Depending on your needs you can choose between an over the sink table KRO and an under the table mount KRU DIMENSIONS A B C D E KRO 0520 390 264 256...

Страница 6: ...is no water in the system If the system line pressure is higher than 5 bars a pressure reducing valve must be installed before the mixed tap When choosing the mixed tap the manufacturer s specificatio...

Страница 7: ...of the mixed tap The water heater is full when bubble free water flows out of the outflow pipe of the mixed tap If the unit is operated without water the heater fuse will be damaged during the first u...

Страница 8: ...is loosened on both sides it can be removed by hand Then remove the thermostat knob and remove the fastening screw below the knob Last unscrew all four fastening screws and the casing can be removed N...

Страница 9: ...p If the unit is put out of action or remains unused for a lengthy period of time then it must be drained and completely isolated from the power supply In rooms permanently subject to frost damage the...

Страница 10: ...49 2 464 2 477 Temperature setting of the thermostat C e smart value 0 0 0 0 Volume l 5 5 5 7 9 8 9 9 Weight full kg 3 5 8 5 4 14 Connected rating W 2000 Connection voltage V 230 Protection class I T...

Страница 11: ...draining off any leaked water must be provided in order to prevent secondary damage in the sense of the product liability provisions 4 The warranty shall not apply in the following cases Improper tra...

Страница 12: ...t and having either failed to meet their exchange or repair obligations or not having done so within a reasonable period 8 The guarantee period shall neither be renewed nor extended as a result of the...

Страница 13: ...sary as a trained professional will inspect the storage tank and analyse the cause of the fault To avoid any confusion regarding the storage tank during transportation it must be provided with a clear...

Отзывы: