TECHNICAL CHARACTERISTICS

 

 

Type

 

 

KRO 0520 

 

KRU 0520 

 

KRO 1020

 

KRU 1020

 

Specified load profile

 

 

XXS 

XXS 

XXS 

XXS 

Energy efficiency class 

1)

 

 

Water treatment energy efficiency (

ƞ

wh) 

1)

 

[%] 

35.2 

35 

35.3 

35.1 

Annual electricity consumption 

1)

 

[kWh] 

525 

527 

523 

525 

Daily electricity consumption 

2)

 

[kWh] 

2.475 

2.49 

2.464 

2.477 

Temperature setting of the thermostat 

[°C] 

e * 

"smart" value 

 

0

 

0

 

0

 

Volume 

[l]

 

5.5 

5.7 

9.8 

9.9 

Weight / full 

[kg]

 

3.5 / 8.5

 

4 / 14

 

Connected rating 

[W]

 

2000

 

Connection voltage 

[V~]

 

230

 

Protection class 

 

Type of protection (protection level) 

 

IP24 

Heating time from 10 °

С

 to 65 °

С

 

[min]

 

10

 

20

 

Dimensions of the packaging 

[mm] 

215x265x425 

275x320x500 

 
* Rotary knob to position "e" means a temperature of about 41°C for KRO/KRU 0520 or about 35°C for KRO/KRU 
1020 
1) Commission regulation EU 812/2013; EN 50440 
2) EN 50440 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание KRO

Страница 1: ...KRO KRU 5 10L...

Страница 2: ...2 INSTRUCTIONS FOR USE 3...

Страница 3: ...e impermissible A defective unit may not continue to be operated Installation and commissioning may only be performed by qualified specialised personnel who therefore assume the responsibility for pro...

Страница 4: ...water preparation within closed spaces and may only be installed with due consideration of the relevant professional standards The unit must be used exclusively in accordance with the conditions set...

Страница 5: ...ll screws with a nominal diameter of at least 5 mm Depending on your needs you can choose between an over the sink table KRO and an under the table mount KRU DIMENSIONS A B C D E KRO 0520 390 264 256...

Страница 6: ...is no water in the system If the system line pressure is higher than 5 bars a pressure reducing valve must be installed before the mixed tap When choosing the mixed tap the manufacturer s specificatio...

Страница 7: ...of the mixed tap The water heater is full when bubble free water flows out of the outflow pipe of the mixed tap If the unit is operated without water the heater fuse will be damaged during the first u...

Страница 8: ...is loosened on both sides it can be removed by hand Then remove the thermostat knob and remove the fastening screw below the knob Last unscrew all four fastening screws and the casing can be removed N...

Страница 9: ...p If the unit is put out of action or remains unused for a lengthy period of time then it must be drained and completely isolated from the power supply In rooms permanently subject to frost damage the...

Страница 10: ...49 2 464 2 477 Temperature setting of the thermostat C e smart value 0 0 0 0 Volume l 5 5 5 7 9 8 9 9 Weight full kg 3 5 8 5 4 14 Connected rating W 2000 Connection voltage V 230 Protection class I T...

Страница 11: ...draining off any leaked water must be provided in order to prevent secondary damage in the sense of the product liability provisions 4 The warranty shall not apply in the following cases Improper tra...

Страница 12: ...t and having either failed to meet their exchange or repair obligations or not having done so within a reasonable period 8 The guarantee period shall neither be renewed nor extended as a result of the...

Страница 13: ...sary as a trained professional will inspect the storage tank and analyse the cause of the fault To avoid any confusion regarding the storage tank during transportation it must be provided with a clear...

Отзывы: