![AURATON S14 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/auraton/s14/s14_user-manual_3017569009.webp)
9
8
1.
Current temperature on the
CH sensor (SR2)
2
. Indicator of the set CH
temperature in the
fireplace circuit,
3
. Indicator of the set
temperature of the
automatically reset
actuator or the second CH
pump,
4.
Indicator of manual activation
of the CH pump,
5.
CH pump operation indicator,
6.
Indicator of operation of a tee valve or the second CH pump,
7.
Indicator of manual activation of a tee valve or the second CH pump.
3.2.7. Manual mode - continuous operation
In order to manually switch on the circulating pump (regardless of the
current temperature at the
SR1
(CH) sensor), press the "
A
" button and
hold it pressed for 3 seconds.
The display will show the hand symbol "
" (
3
). If you wish to switch off
the pump's manual operation, press the "
A
" button again and hold it
pressed for 3 seconds.
NOTE: When only the SR1 sensor is connected, the remaining functions
of the controller are inactive, i.e. there is no indication of operation of
CH pumps in the fire place circuit and of the control of the pump in the
HDW circuit.
[h]
3.3. Diagram of connection of the controller with
the pump at the CH boiler
0
I
A
B
C
D
SR1 SR2 SR3
OUT1
OUT2
OUT3
OUT4
OUT5
IN
CH
boiler
Pump
230V
mains power supply
Temperature sensor
(fix with a band)
4
Description of a controller working with
a CH pump and an automatically reset
actuator, or with a second CH pump -
a fireplace boiler stove circuit
(part B of the display)
4
6
7
1
5
B
2
3
AURATON S14
in a circuit with a boiler stove fireplace uses two control
outputs:
one for the water pump in the fireplace circuit;
ź
one for an actuated valve or the second pump, which is required for
ź
proper cooperation between the boiler stove fireplace with the CH
circuit.
After the power supply is switched on, temperature in the water jacket of
the boiler stove fireplace is measured (with the digital sensor); the
temperature signal can be divided into two independent channels.
Depending on the temperature of water in the fireplace circuit, the
controller automatically starts or stops the CH pump of the fireplace and
starts the valve or the second pump.
The
AURATON S14
controller also has the
GUARD
functions which
prevents the stalling process in the rotor of the pump when it is not in use.
After the heating season,
AURATON S14
automatically starts the pump
for 30 seconds every 14 days.
In order for the system to work after the heating season, the controller
must be switched on at all times.