4.1.3. Connecting the power supply cable of the CH pump

The CH pump must be connected to the 

OUT2

 (

L

,

 ,

N

). terminals. In the 

pump, connect the green or yellow-green wire (grounding or protective 
zero) to the "

" terminal, the blue wire - to the "

N

" terminal, and the 

brown wire - to the "

L

" terminal.

[u]

[u]

11

10

4.1. Installation

4.1.1. Mounting the controller

T

he controller must be mounted on a wall or another support using two 

screws  (the  concrete  anchors  with  screws  are  delivered  with  the 
controller). The cables extending from the controller must be fixed to the 
wall with cable clips. 

4.1.2. Mounting the sensor

Before installing the cables, remove the protective plugs by cutting them 
off.  In  the  controller,  connect  the  temperature  sensor  to  the 

SR2

 

terminals. Then install the sensor on the outside of the fireplace's water 
jacket or on an uncovered outlet pipe connected to the CH boiler (as close 
to the boiler as possible). The sensor must not be immersed in liquids or 
installed at the fireplace smoke outlets.

4.1.4. Connecting the power supply cable to the valve (or the 

second CH pump)

In  the  controller,  the  valve's  cable  must  be  connected  to  the 

OUT3

 

terminal (

L

,

 ,

N

).  In the valve, connect the green or yellow-green wire 

(grounding or protective zero) to the terminal (grounding symbol), the 
blue wire - to the "

N

" terminal, and the brown wire - to the "

L

" terminal. 

[u]

4.1.5. Connecting the controller  

After the wires are secured to prevent accidental ripping, connect the 
power  supply  cable  on  the  side  of  the  controller  to  the

 

IN

 (

L

,

N

) terminals. Then connect the cable to a 230V AC/50 Hz power 

outlet with a grounding pin. 

4.2. Operation of the controller

4.2.1. Switching the controller on 

Set  the  power  supply  switch 

in  the  "

I

"  position.  After  power  is 

switched  on,  all  segments  of  the  display  light  up.  Then  the  controller 
indicates the current temperature of measured by the sensor. 

[on/o

0

I

4.2.2. Settings range

 

Temperature (from 0°C to 99°C) is measured by the 

SR2

 sensor,

ź

The CH pump is controlled using the 

OUT2

 output,

ź

The automatically reset actuator and the second CH pump is controlled 

ź

using the 

OUT3

 output,

The  settings  range  for  the  CH  pump  and  the  automatically  reset 

ź

actuator (or the second CH pump) is equal to 10°C to 85°C, and the 
hysteresis (the temperature difference between the start and the stop 
settings) is adjustable in the range of 2°C to 10°C.

4.2.3. Changing the temperature 

Press the "

B

" button for a short time. When the CH set temperature 

indicator (left) in the fireplace circuit starts blinking, use the "+" or "-" 
button to set the desired temperature.
Press  the  "

B

"  button  again.  When  the  CH  set  temperature  indicator 

(right) of the valve or the second CH pump in the fireplace circuit starts 
blinking, use the "+" or "-" button to set the desired temperature. After 
the  value  is  set, approve  it  (within  10  seconds)  by pressing  the  "

OK

button. Otherwise, the changed value will not be saved and the controller 
will return to the previous setting.

4.2.4. Changing the hysteresis 

Press the "

B

" button under the temperature setting. The digits begin to 

blink and indicate the value of the current setting (left indicator). When 
the "

B

" button is pressed again, the right temperature indicator starts 

blinking. Press the "

B

" button in order to edit the value of hysteresis (

HI

), 

in the range of 2°C to 10°C, for the CH pumps (left indicator). Then use the 
"+"  or  "-"  button  to  set  the  required  hysteresis  value.  When  the  "

B

button is pressed again, the hysteresis (HI) is set, in the range of 2°C to 
10°C, for the valve or the second CH pump (right indicator). Then use the 
"+" or "-" button to set the required hysteresis value. After the value is 
set, approve it (within 10 seconds) by pressing the "

OK

" button.

Otherwise, the changed setting will not be saved and the controller will 
return to the previous setting. 

Example: If the temperature setting is 40°C and the hysteresis is 4°C, the 
pump will start at 42°C and will stop at 38°C. 

NOTE: The ambient temperature in the place where the controller 

is installed must not exceed 40 °C.

NOTE:  The  wires  and  cables  may  be  connected  only  when  the 

power supply is cut off.

!

Содержание S14

Страница 1: ...User manual www auraton pl S14 dla oprogramowania w ver F03 oraz F0A ...

Страница 2: ...1 ThedisplayoftheAURATONS14controllerisdividedintofourparts Eachpartcorrespondstoaseparatedevicesupportedbythecontroller PartA Controlofthecentralheating CH pump PartB Control of the central heating CH pump the automatically reset actuator or the second central heating pump in the fireplacecircuit PartC Controlofthehotdomesticwater HDW circulatingpump PartD Controlofthefan blower ON OFF S MIN STOP...

Страница 3: ...ors 2 User ssetting 3 Counted operation time of the fan and the duration of the interval betweentheblow throughs 4 Indicatorofextinguishedfireinthefurnace 5 Indicatorofemergencyshutdownofthefan 6 Indicatorofmanualactivationofthedevice 7 Indicatorofignition 8 Indicatoroffanpowerpercentagevalue 9 Indicatorofforcedoperation oftheCHpump 10 Indicatorofsustainedfireinthefurnace ...

Страница 4: ... provided with an approx 2 5 m long cable If an expanded functionality of the controller is required additional temperature sensors must be bought option If the length of the cable is inadequate a sensor with an approx 15 m long cable can be purchased 4 1 2 3 4 5 6 7 8 0 I A B C D SR1 SR2 SR3 OUT1 OUT2 OUT3 OUT4 OUT5 IN Description of buttons and cable terminals 2 NOTE Inordertoaccessthecabletermi...

Страница 5: ...to circulate in a CH system with a coal fired boiler or a gas boiler without a system controlling the operation of the pump The controller s sensor measures the temperatureofthewateronthesupplysideoftheCHsystem In a CH system with a coal fired boiler the controller switches off the circulation pump after the flame in the boiler is extinguished Pumping of water is not recommended when the flame is ...

Страница 6: ...ing them off In the controller connect the temperature sensor to the SR1 terminals Then install the sensor on an uncovered outlet pipe connected totheCHboiler asclosetotheboileraspossible NOTE If a coal fired boiler and a gas fired boiler work in the same CH system the sensor should be installed in a location where the two outletsmergeandmustbeinsulated 3 1 4 Connection check Checkifthewireisconne...

Страница 7: ...topat38 C 3 2 5 Changing the forced pump operation mode Press the A button under the temperature setting The digits begin to blink and indicate the value of the current setting Display the hysteresis setting HI by pressing the A button again After you press the A button one more time the value of 85 C will be displayed in the temperature section and on the right side of the display the symbol of f...

Страница 8: ...n again and hold it pressedfor3seconds NOTE When only the SR1 sensor is connected the remaining functions of the controller are inactive i e there is no indication of operation of CH pumps in the fire place circuit and of the control of the pump in the HDWcircuit h 3 3 Diagram of connection of the controller with the pump at the CH boiler 0 I A B C D SR1 SR2 SR3 OUT1 OUT2 OUT3 OUT4 OUT5 IN CH boil...

Страница 9: ... stove fireplace uses two control outputs oneforthewaterpumpinthefireplacecircuit ź one for an actuated valve or the second pump which is required for ź proper cooperation between the boiler stove fireplace with the CH circuit After the power supply is switched on temperature in the water jacket of the boiler stove fireplace is measured with the digital sensor the temperaturesignalcanbedividedinto...

Страница 10: ...e immersed in liquids or installedatthefireplacesmokeoutlets 4 1 4 Connecting the power supply cable to the valve or the second CH pump In the controller the valve s cable must be connected to the OUT3 terminal L N In the valve connect the green or yellow green wire grounding or protective zero to the terminal grounding symbol the bluewire tothe N terminal andthebrownwire tothe L terminal u 4 1 5 ...

Страница 11: ...ain When the CH set temperature indicator right of the valve or the second CH pump in the fireplace circuit starts blinking use the or button to set the desired temperature After the value is set approve it within 10 seconds by pressing the OK button Otherwise the changed valuewillnot be saved and the controller willreturntotheprevioussetting 4 2 4 Changing the hysteresis Press the B button under ...

Страница 12: ...anged setting willnotbesavedandthecontrollerwillreturntotheprevioussetting 4 2 6 Automatic operation The controller starts or stops the pump and the valve depending on the set temperature value In the CH system the pump and the valve are started when the temperature in the location of the sensor exceeds the set value and stopped when the temperature drops below the value set in the controller taki...

Страница 13: ...lementsnecessaryforproperoperationofthesystem 1 7 2 3 4 5 8 9 6 230V mains power supply 0 I A B C D SR1 SR2 SR3 OUT1 OUT2 OUT3 OUT4 OUT5 IN 1 Boiler stove fireplace 6 Radiator 2 Cut offvalve 7 Compressionvessel 3 Pump 8 Temperaturesensor 4 Exchanger 9 CHboiler 5 Automaticallyresetactuator NOTE When only the SR2 sensor is connected the remaining functions of the controller are inactive i e there is...

Страница 14: ...oller working with a hot domestic water HDW pump part C of the display C 4 5 1 2 3 5 5 1 Operation with the HDW over CH priority switched on If the HDW over CH priority function is switched on then the pump in the HDW circuit depends only on the setting and on the temperature measuredbytheSR3sensorinstalledinthetank 5 1 1 Settings range Temperature from 0 C to 99 C is measured by the SR3 sensor Th...

Страница 15: ...rinthetank 5 1 2 Programming of the HDW functions When the button is pressed the value of 50 C factory setting starts blinking Usethe or buttontosetthedesiredtemperature Once the desired temperature value is set it must be confirmed do not forget to do so within 10 seconds by pressing the button Otherwise the changed value will not be saved and the controller will returntotheprevioussetting After ...

Страница 16: ...sor On the controller side the temperature sensor must be connected to the SR3 terminals and then installed in the hot domestic water tank The sensor must not be immersed in liquids or installed at the fireplace smoke outlets Themaximummeasuredtemperaturevalueis99 C 5 2 1 Manual mode continuous operation In order to manually switch on the circulating pump regardless of thecurrent temperature at th...

Страница 17: ...ll not be saved and the controllerwillreturntotheprevioussetting 5 4 3 Changing the hysteresis Press the C button under the temperature setting The digits begin to blink and indicate the value of the current setting Display the hysteresis setting HI by pressing the C button again Using the or button set the required hysteresis value in the range of 2 C to 10 C with a 2 C increment After the value ...

Страница 18: ... displays the value of 85 C which means that above this temperature value measured by the SR1 sensor the CH pump will be started in the A section On the other hand section C setting value displays the value of 85 C which means that the tank will collect heat but only to the value of 85 C SR3 Also the forced operation indicator the CH pump is switched on is displayed After the value is set approve ...

Страница 19: ... indicator 11 Settimeunit S second MIN minute on hedoff ature of ding of begin to Display en press r hing the nd blink hen the button of 85 C the SR1 e other h means Also the splayed sing the and the ere the 5 C and In such mp in the p in the witched er supply V mains 0 IN 5 5 2 With the HDW tank Pump HDW sensor HDW tank 0 I A B C D SR1 SR2 SR3 OUT1 OUT2 OUT3 OUT4 OUT5 IN NOTE When only the SR3 se...

Страница 20: ...be connected to the OUT5 terminal L N In the blower connect the green or yellow green wire grounding or zero to the terminal the blue wire to the N terminal andthebrownwire tothe L terminal 6 1 1 Mounting the controller The controller must be mounted on a wall or another support using two screws the concrete anchors with screws are delivered with the controller The cables extending from the contro...

Страница 21: ...temperature value is set it must be confirmed do not forget to do so within 10 seconds by pressing the OK button Otherwise the changed value will not be saved and the controller will returntotheprevioussetting 6 2 4 Changing the operation time and the time of periodic breaks in the fan s operation Press the D button once The fan temperature will start blinking If you press the D button again withi...

Страница 22: ...emperature value Once the desired temperature value is set it must be confirmed saved within 10 seconds by pressing the OK button Otherwise the changed setting will not be saved and the controller will returntotheprevioussetting 6 2 6 Changing the hysteresis To change the hysteresis value press the D button and display the fan temperature If you press the D button again the fan operation time and ...

Страница 23: ...ere 100 is the maximum fan power value In order to change the fan power press the D button and display the fan temperature If you press the D button again the fan operation time and the break time settings will be displayed By pressing the D button yet again you will display the definitive fan switch off temperature and the STOP LO text Press the D button one more time and set the desired hysteres...

Страница 24: ...o switch off and then switch on again the controller using the switch in ordertostarttheignitionfunction 0 I 0 I 6 2 11 Adding fuel to the furnace During normal operation fuel can be added with the operation of the fan blocked intwoways Switch off the controller using the switch Add fuel and then ź switch on the controller and start the ignition function at the same time The second method consists...

Страница 25: ...ress and hold the OK button and the button for about 3 seconds The activation ofthepermanentilluminationisconfirmedwithasoundsignal The permanent illumination can be switched off by pressing the OK and button simultaneously The deactivation of the permanent illuminationisconfirmedwithasoundsignal NOTE The first time any function button is pressed the illumination is switchedonfirst ifthepermanenti...

Страница 26: ...t stop f 2 10 Supply voltage 230V 50Hz Maximum load for output sum 6A C C C C diff rom C to C A Data pertaining to the controller working in a CH circuit Temperature settings range 10 85 Range of measured values 0 99 Hysteresis start stop f 2 10 Supply voltage 230V 50Hz Maximum load for output sum 6A C C C C diff rom C to C B Data pertaining to the controller working with a CH pump and valve Z or ...

Страница 27: ...a pertaining to the controller working with a fan Cleaning and maintenance ź The outside of the controller must be cleaned with a clean cloth Do not use solvents suchasbenzene thinners oralcohol ź Do not touch the device with wet hands This can lead to electric shock or seriousdamagetothedevice ź Nonotexposethedevicetoexcessiveimpactofsmokeordust ź Donottouchthedisplaywithsharpobjects ź Avoidconta...

Страница 28: ...www auraton pl ...

Отзывы: