3.2.1. Switching the controller on
ut the switch
n the "
I
" position. After the controller is switched
on, all segments of the display are lit for about 2 seconds and the software
version is displayed. Then the "
symbol, the current sensor
temperature (
4
), and the set temperature (
5
) are shown on the display.
P
i
"
[butt]
grzej]
3.1.3. Connecting the power supply cable of the pump
In the controller, the pump's cable must be connected to the OUT1
terminal. In the pump, connect the green or yellow-green wire
(grounding or protective zero) to the " " terminal and connect the blue
wire to the "
N
" terminal. Connect the brown wire to the "
L
" terminal.
3.1. Installation
3.1.1. Mounting the controller
The controller must be mounted on a wall or another support using two
screws (the concrete anchors with screws are delivered with the
controller). The cables extending from the controller must be fixed to the
wall with cable clips.
3.1.2. Mounting the sensor
Before installing the cables, remove the protective plugs by cutting them
off. In the controller, connect the temperature sensor to the
SR1
terminals. Then install the sensor on an uncovered outlet pipe connected
to the CH boiler (as close to the boiler as possible).
NOTE: If a coal-fired boiler and a gas-fired boiler work in the same CH
system, the sensor should be installed in a location where the two
outlets merge and must be insulated.
3.1.4. C
onnection check
Check if the wire is connected properly and fix the lid of the pump motor's
compression box with screws.
3.1.5. Connecting the controller
NOTE: The wires and cables may be connected only when the
power supply is cut off.
After the wires are secured to prevent accidental ripping, connect the
power supply cable to a 230V AC/50 Hz power outlet with a grounding
pin.
NOTE: The ambient temperature in the place where the controller
is installed must not exceed 40°C.
3.2. Operation of the controller
0
I
3.2.3. Changing the temperature
Press the "
A
" button under the temperature setting. The digits begin to
blink and indicate the value of the current setting. Using the "+" (increase)
or "-" (decrease) button, set the desired temperature. After the
temperature value is set, approve it (within 10 seconds) by pressing the
"
OK
" button. Otherwise, the changed value will not be saved and the
controller will return to the previous setting.
3.2.4. Changing the hysteresis
Press the "
A
" button under the temperature setting. The digits begin to
blink and indicate the value of the current setting. Display the hysteresis
setting (
HI
) by pressing the "
A
" button again. Using the "+" or "-" button,
set the required hysteresis value in the range of 2°C to 10°C (with a 2°C
increment). After the value is set, approve it (within 10 seconds) by
pressing the "
OK
". Otherwise, the changed setting will not be saved and
the controller will return to the previous setting.
Example: If the temperature setting is 40°C and the hysteresis is 4°C, the
pump will start at 42°C and will stop at 38°C.
3.2.5. Changing the forced pump operation mode
Press the "
A
" button under the temperature setting. The digits begin to
blink and indicate the value of the current setting. Display the hysteresis
setting (
HI
) by pressing the "
A
" button again. After you press the "
A
"
button one more time, the value of 85°C will be displayed in the
temperature section and on the right side of the display the symbol of
forced pump operation ( ). Za pomocą przycisku „
+
” lub „
–
” will be
shown. Using the "+" or "-" button, select a setting where, after the
temperature exceeds 85°C, the pump is in continuous operation ( ) or
shuts down ( ).
After the pump operation mode is set, approve it (within 10 seconds) by
pressing the "
OK
" button. Otherwise, the changed setting will not be
saved and the controller will return to the previous setting.
^
^.
^
3.2.6. Automatic operation
After this operation mode is set, the controller starts and stops the pump
depending on the set temperature. In the CH system, the pump is started
when the temperature in the location of the sensor exceeds the set value
and stopped when the temperature drops below the value set in the
controller, taking into account the hysteresis.
3.2.2. Description of the display
The top part of the display (
4
) shows the current temperature of the
sensor while the bottom part (
5
) shows the set temperature. Movement
of the blades on the indicator (
1
) indicates operation of the CH pump.
!