20
Assembly Instruction
KS 4 S12 24V DC
05
(D
riVe
at
SiDe
/ t
anDem
)
nsK
I
nstallatIon
step
6
a
:
h
ole
layout
:
CaSement
braCKet
f42
Rigid drive mounting directly on the window frame - auxillary closing edge - inward opening windows
Tandem application / Combination right / left
22
15
min. 27
17
• only for bottom-hung casements
- inward opening windows
• respect max. pulling forces of drives.
• cable exit (power supply) on top.
From FAB > 1200 mm
is a locking drive required!
!
24 V DC
5
4,2
30
M4
220
18
A
C B
22
> FAH / 2
bzw. min. Hub
FAB = max. 1200
FAH
= min
. X
19
stroke
a
b
c
X
Max.
opening
200
205
455
425
≥ 450
45°
300
301
551
521
≥ 650
50°
400
301
551
521
≥ 650
60°
500
415
665
635
≥ 850
60°
600
415
665
635
≥ 850
60°
800
505
755
725
≥ 1050
60°
1000
618
868
838
≥ 1250
60°
F42
Ks4
FL
RA
F42
Ks4
view:
see below
top
baseplate
reference edge
frame
b
raCkets
anD
C
asement
b
raCkets
or min strok
e
Содержание KS4 S12 24V DC R