31
Assembly Instruction
KS 4 S12 24V DC
07
24
V DC
24
V DC
e
leCtriC
ConneCtion
The
a
umüller
-Click
plug solution
enabling the use of
site-supplied cable. It simplifies assembly and the electrical
connection of the drives.
Loosen the screws
and remove the housing cover
.
On the underside of the plug housing
are two
openings for releasing the locking hooks.
Push locking hook with a screwdriver inwards - and
depress simultaneously.
Replace cable set - provided by the customer in place of
connecting cable.
Moung the housing cover
with the both screws
.
Locking hooks - at the housing cover
-
prevent withdrawal of the plug under tensile
load.
Five terminals
to 1,5 mm
2
.
The performances (especially the fire be-
havior) of locally provided cables, must be
checked on own responsability on com-
pliance with the application-specific local
regulations!
n
ote
n
ote
a
umüller
-Click
plug solution
-
Site
-
SupplieD
CuStomiSeD
ConStruCtion
2
2
3
1
1
1
1
3
Locking hooks
Openings for releasing the
locking hooks
Push locking hook with a
screwdriver inwards - and
depress simultaneously
3
4
AK
Connection assignment
Function
Colour
DIN IEC 757
OPEN / CLOSE
blue
BU
OPEN / CLOSE
brown
BN
Data
white
WH
Rel: NO
violet
VT
Rel: NO
green
GN
Содержание KS4 S12 24V DC R