14.
Technical data
Information
The following tables include standard and optional features. For detailed information
on the customer-specific version, refer to the order-related data sheet. The technical
data sheet can be downloaded from the Internet in both German and English at ht-
tp://www.auma.com (please state the order number).
14.1.
Technical data Globe valve actuator
Valve shaft
Max.
Valve attach-
ment
Run torque
2)
/
modulating
torque
3)
Torque
range
1)
Speed rpm
(adjustable in 9 steps)
Type
Two-flat
Max. [mm]
Square
Max. [mm]
Cylindrical
Max. [mm]
Standard
EN ISO 5211
Max.
[Nm]
Max.
[Nm]
50 Hz/60 Hz
17
17
20
F07
13
10 – 25
1.6 – 22
SVM/SVMR 05.1
22
22
25.4
F07
25
20 – 50
1.6 – 22
SVM/SVMR 07.1
22
22
25.4
F10
50
40 – 100
0.6 – 8.0
SVM/SVMR 07.5
The “Torque by-pass” function (can be activated) allows increasing the pre-set torque to 130 %. This increase only applies during actu-
ator start for a limited time period. This allows safer unseating of blocked valves.
1)
Permissible average torque in open-close duty S2 - 15 min
2)
Torque in modulating duty S4 - 40 %
3)
Weight aluminium
2)
Weight bronze
2)
Handwheel/crank handle according to VG
85081
1)
Speed rpm
(adjustable in 9 steps)
Type
approx. [kg]
approx. [kg]
Turns for 90°
∅
[mm]
50 Hz/60 Hz
7.5
11
13:1
125
1.6 – 22
SVM/SVMR 05.1
10.5
17
13:1
125
1.6 – 22
SVM/SVMR 07.1
10.5
17
13:1
125
0.6 – 8.0
SVM/SVMR 07.5
Hub does not correspond to VG 85081; other versions on request
1)
Indicated weight includes globe valve actuator with controls, electrical connection in standard version, unbored coupling and hand-
wheel/hand crank.
2)
Features and functions of actuator
Short-time duty S2 - 15 min
Open-close duty:
Type of duty
Intermittent duty S4 - 40 % with maximum number of starts of 1,800 cycles per
hour (option)
Modulating duty:
For nominal voltage and 40 °C ambient temperature and at average running or modulating torque load
The type of duty must not be exceeded.
Variable speed, brushless motor
Motor
F, tropicalized
Insulation class
PTC thermistors (according to DIN 44081)
Motor protection
●
Bronze
●
Aluminium
Options:
Housing material
Yes
Self-locking
Via position transmitter potentiometer status signals for directions OPEN and CLOSE
Turns per stroke: 1 – 110
Signalling via fieldbus interface
Limit switching device
Via electronic current measurement status signals for directions OPEN and CLOSE, adjustable in 8
steps
Signalling via fieldbus interface
Torque switching
Continuous indication, adjustable indicator disc with symbols OPEN and CLOSED
Mechanical position indicator
Manual drive for setting and emergency operation, handwheel does not rotate during electrical operation
Manual operation
42
SVM 05.1 – SVM 07.5 / SVMR 05.1 – SVMR 07.5
Technical data
Modbus RTU
Содержание SVM 05.1
Страница 49: ...49 SVM 05 1 SVM 07 5 SVMR 05 1 SVMR 07 5 Modbus RTU...
Страница 50: ...50 SVM 05 1 SVM 07 5 SVMR 05 1 SVMR 07 5 Modbus RTU...
Страница 55: ...55 AUMA worldwide...