6.2.
S/SH/SD electrical connection (AUMA plug/socket connector)
Figure 25: S, SH and SD electrical connection
[1]
Cover
[2]
Socket carrier with screw-type terminals
[3]
Terminal compartment (in cover)
[3A]
Cable entries for mains connection (pins for motor and pins for controls)
[3B]
Cable entries for HART cables
Short description
Plug-in electrical connection with screw-type terminals for pins for motor and pins
for controls. Pins for controls also available as crimp-type connection as an option.
S version (standard) with three cable entries. SH version (enlarged) with additional
cable entries. For cable connection, remove the AUMA plug/socket connector and
the socket carrier from cover.
Technical data
Table 11:
Electrical connection via AUMA plug/socket connector
Control contacts
Power contacts
50 pins/sockets
6 (3 equipped) + protective
earth conductor (PE)
No. of contacts max.
1 to 50
U1, V1, W1, U2, V2, W2, PE
Designation
250 V
750 V
Connection voltage max.
16 A
25 A
Rated current max.
Screw connection, crimp-type (option)
Screw connection
Type of customer connection
2.5 mm
2
(flexible or solid)
6 mm
2
(flexible)
10 mm
2
(solid)
Connection diameter max.
28
SAV 07.2 – SAV 16.2 / SARV 07.2 – SARV 16.2 Control unit: electronic (MWG)
Electrical connection
ACV 01.2 HART