3 - INTRODUCTION
3.1 - General information
The
Pilot
is a hydraulic pilot which ensures the control of one or
more heating circuits (with options).
The
Pilot
is meant to be connected to an
HRC
70
or
HTI
70
range heat
pump.
The
Pilot
is delivered ready to use in its factory set confi guration
(see § «Set-up»)..
However, we strongly recommended the use of the «Start-up»
function proposed at the fi rst powering of pilot. It allows for use to
be personalised for the household.
This confi guration and its settings can be modifi ed in the expert
menu.
Equipments
Integrated electric heater for back-up
0 to 6 kW
Mulifunctional tank ensuring the uncoupling of
the hydraulic circuits
38 litres
Electronic control taking charge of the optimal
management of the installation
Essential components for the protection of
the hydraulic circuits (pressure relief valves,
automatic purgers, pressure sensors)
Scheduled programming of the comfort mode
for the 7 days of the week using programmable
ranges
3.2 - Packaging
Weight
(kg)
Number
of
packages
W
(mm)
H
(mm)
P
(mm)
54
1
670
600
880
3.3 - Accessories (included)
Each
Pilot
is delivered with (non-mounted):
• Exterior sensor
Gives the pilote the outside
temperature to adapt its heating set
point
3.4 - Accessories available as optional
extras
3.4.1 - Installation
• 2
nd
heating circuit
2nd heating circuit at the same temperature
Allows distribution of a second heating circuit controlled by a
thermostat (TA) (
Ref. 753105
)
• Wall mounting bracket
Eases the installation on the wall.
• USB memory stick
Allows downloading of the operating
history
Be sure to keep the original delivered USB fl ash drive.
It will facilitate your exchanges with your technical contacts.
3.4.2 - Control
• Ambient temperature thermostat radio non-
chronoproportional -(TH
Rnc
)-
(type on/off ). Wireless, programmable thermostat,
transmitting through radio-frequency. Necessary when a wired
connection between the Pilot and the ambient temperature
thermostat is not possible
(
Ref. 770001
)
• Ambient temperature thermostat
(TA)
2 wires - allows to control the temperature
in the heating zone
(
Ref. 710043
)
• Ambient temperature sensor (SA)
2 wires - allows to control the temperature
of the heating zone on a variety of comfort
levels (programmable from the pilot).
(
Ref. 751009
)
• DHW sensor
For the production of domestic hot water
(
Ref. 710029
)
●
2-core sheathed cable
(Ref. 753102)
linking the Heat Pump and the Pilot
(20m long)
20m length for connection instead of the
10m length delivered as standard.