INSTALLATION
PILOT
-C14-
MANUAL
-
4
Danger of death if the pressure relief valves
are missing or defective
A defective pressure relief valve may prove
dangerous and could lead to burns or other
injuries by, for example, the pipes bursting.
The information presented in this document does
not contain all of the schematic diagrams needed
for a professional installation of the pressure relief
valves.
• Install the necessary pressure relief valves on
the circuit.
• Inform the user concerning the function and
the placement of the pressure relief valves.
• Respect all applicable national and international
regulations, standards and decrees.
Risk of corrosion
The appliance should be installed in an area
where it is not exposed to humidity and without
any risk of being splashed by water.
Risk of damage related to frost
The pilot MUST be installed in an area where it is
not subject to frost or freezing.
Risk of material damage
The pilot can only work when fi lled with water.
Never switch on the appliance if it is not
completely fi lled with water and purged of air.
Rules and regulations (decrees, standards,
laws)
Once the appliance is installed and switched
on, all decrees, directives, technical rules, safety
measures and standards, must be respected in
their current version in eff ect.
The electrical supply must conform to all
applicable regulations in the country of
installation, as well as the NFC 15-100 standard.
• A method of disconnection ensuring a complete
cut-off must be installed in the fi xed piping to
conform to installation regulations (do not use
a movable outlet).
• Protect the appliance with a 2-pole circuit
breaker with a minimum contact opening of
3mm and must be grounded.
•
If the electrical supply cable is damaged, it
must be replaced by the manufacturer, their
customer service technicians, or by a qualifi ed
professional to prevent any risk of injury or
danger.
• The devices for electrical cut-off must remain
accessible.
• Water and/or R290 fl ammable gas can fl ow
through the discharge pipe of the pressure
limiting device (safety valve). This pipe must
be kept open outside the building.
The end of
this pipe must be placed downwards (see §
Connecting the pressure relief valve).
Maintenance - Troubleshooting
Maintenance and cleaning of the pilot must be
carried out at least once a year by a qualifi ed
professional.
This appliance is in compliance with the
international standards concerning electrical
safety CEI 60335-1, CEI 60335-2-102. The
CE branding on the appliance attests to its
compliance with the following directives:
- Low voltage (LV): 2014/35/UE
-
Electromagnetic compatibility
(CEM):
2014/125/CE
- Ecodesign concerning products related to
energy: 2013-813-UE