Page 29
LIVEtouch20
- 20 Channel Digital Mixing Console
English
5-3-4 GEQ sub-page
1
2
3
4
6
5
1
- Modules selection
Use the left and right arrows to select the module to be set.
2
- Library
The library allows you to save and load the user's equalization settings. Click the drop-down menu and select a
library entry from the list to load its settings. Click the "Save" button and select the desired library location (1 - 16)
from the list to save the current EQ settings. A virtual keyboard will appear on the screen to enter a name for the
setting. Finally, click "confirm" to save the setting or "cancel" to cancel.
3 - Graphic equalizer
The right side displays the gain amplitude (+18, 0, -18 dB), the upper part displays the frequency and gain value
(default 0dB). Drag the sliders up and down to adjust the gain for each frequency, or use the corresponding physi-
cal faders to do so.
4 - Opérations
Bypass
: Turns the equalizer on or off.
Flat
: Reset all sliders to 0 dB.
Type
Min.
Max.
Default
Hall Bright
0.8 s
12.0 s
1.6 s
Hall Warm
Room Bright
0.4 s
8.0 s
0.8 s
Room Warm
Plate Bright
0.4 s
6.0 s
0.6 s
Plate Warm