Session Border Controllers
45
Mediant 4000B SBC
Hardware Installation Manual
5. Cabling the Device
5.3.3
Cabling for Remote Connectivity (Post-Initial Setup)
Once you have installed and configured your operating system and third-party application,
you can connect remotely to the OSN server through your network, using protocols such as
remote desktop (RDP) or Telnet (SSH). The connection to the OSN server is through the
Ethernet port(s) on the OSN4 module.
To connect to the LAN interface:
1.
Connect an RJ-45 connector, on one end of a CAT 5 (5e or 6) cable, to one of the
Gigabit Ethernet ports on the OSN4 module. For connector pinouts, see
Table 5-3
.
2.
Connect the other end of the cable to your network.
Figure 5-9: Cabling OSN4 Module to Network
The RJ-45 connector pinouts for the Gigabit Ethernet interface are listed in the table below:
Table 5-3: RJ-45 Connector Pinouts for Gigabit Ethernet Interface on OSN4 Module
Pin
100Base-Tx
1000Base-T
I/O
Signal
Signal
Function
1
0
Tx+
I/O
BI_DA+
2
0
Tx-
I/O
BI_DA-
3
I
Rx+
I/O
BI_DB+
4
-
-
I/O
BI_DC+
5
-
-
I/O
BI_DC-
6
I
Rx-
I/O
BI_DB-
7
-
-
I/O
BI_DD+
8
-
-
I/O
BI_DD-