the heater power is more than 1400 watts, the volume of the pot is also limited to
less than 10 gallons (or 38 liters). Due to its compact size and the splash proof
design for kitchen applications, the controller has a limited ability to dissipate the
heat generated by the internal solid state relay during the initial heat up. The initial
full power heat up process cannot be more than 90 minutes. If you have a pot that
is larger 5 gallons (19 litters), please read Appendix 1 “Managing the heat
generated by the controller
”
•
Always place the sensor in the controlled subject when the controller is on. Before
turning on the controller, please make sure the sensor is placed inside the
container to be controlled. Leaving the sensor outside of the solution will form an
open loop operation. If the sensor is left outside, controller will assume the
temperature is low even if the controlled subject is already very hot. The controller
will provide full power to the heater. It will not only overheat the controller, but also
damage your appliance, and even cause a fire.
•
The 16 AWG power cord provided with controller is specially designed for high
power applications. Do not replace it with regular computer power cord when
heating device is more than 1200 watts.
•
This controller is designed to control the devices recommended by Auber
Instruments only. Using it to control a not recommended device can be dangerous
and cause fire. Auber Instruments is not liable for damages caused by misuse of
the controller. If you are not sure the controller can be used, please contact Auber
Instruments before use.
•
If an abnormal display or noise is observed, turn the controller off, unplug the
power cord and contact the manufacturer before using it again.
•
Clean the controller only when it is cool and unplugged.
•
Do not allow children to operate the controller.
Specifications
Input voltage:
100 to 240 VAC 50 /60 Hz
Output voltage:
Same as the input.
Maximum Current:
15A.
Fuse Size:
15A Fast blow.
Controller Mode:
PID, PI, PD or P.
Output switching device:
Built-in optically isolated solid state relay with zero voltage
crossing switching.
Sensor tip dimensions:
4 mm diameter x 40 mm long.
Sensor cable length:
5 ft (1.5 m)
Timer Range:
0.1 to 99.9 hours for each step, 6 steps total l
Temperature resolution:
1 °C or 1 °F
T emperature display range:
-10 to 200 °C or 14 to 392 ° F
Temperature control range:
+5 °C (°F) from room temperature to 195 °C (383 °F)
2