background image

the heater power is more than 1400 watts, the volume of the pot is also limited to 
less than 10 gallons (or 38 liters). Due to its compact size and the splash proof 
design for kitchen applications, the controller has a limited ability to dissipate the 
heat generated by the internal solid state relay during the initial heat up. The initial 
full power heat up process cannot be more than 90 minutes. If you have a pot that 
is larger 5 gallons (19 litters), please read Appendix 1 “Managing the heat 
generated by the controller

” 

  Always place the sensor in the controlled subject when the controller is on. Before 

turning on the controller, please make sure the sensor is placed inside the 
container to be controlled. Leaving the sensor outside of the solution will form an 
open loop operation. If the sensor is left outside, controller will assume the 
temperature is low even if the controlled subject is already very hot. The controller 
will provide full power to the heater. It will not only overheat the controller, but also 
damage your appliance, and even cause a fire.   

  The 16 AWG power cord provided with controller is specially designed for high 

power applications. Do not replace it with regular computer power cord when 
heating device is more than 1200 watts. 

  This controller is designed to control the devices recommended by Auber 

Instruments only. Using it to control a not recommended device can be dangerous 
and cause fire. Auber Instruments is not liable for damages caused by misuse of 
the controller. If you are not sure the controller can be used, please contact Auber 
Instruments before use. 

  If an abnormal display or noise is observed, turn the controller off, unplug the 

power cord and contact the manufacturer before using it again. 

  Clean the controller only when it is cool and unplugged. 

  Do not allow children to operate the controller.   

Specifications 

Input voltage:

   

100 to 240 VAC 50 /60 Hz 

Output voltage:

   

Same as the input.   

Maximum Current:

  

15A. 

Fuse Size:

 

15A Fast blow. 

Controller Mode:

   

PID, PI, PD or P. 

Output switching device:

    Built-in optically isolated solid state relay with zero voltage 

crossing switching.   

Sensor tip dimensions:

   

4 mm diameter x 40 mm long.   

Sensor cable length:

 

5 ft (1.5 m) 

Timer Range:

 

0.1 to 99.9 hours for each step, 6 steps total l 

Temperature resolution:

   

1 °C or 1 °F 

T emperature display range:   

-10 to 200 °C or 14 to 392 ° F 

Temperature control range:

 +5 °C (°F) from room temperature to 195 °C (383 °F) 

 
 

2

 

 
 

Содержание WS-1500APH

Страница 1: ...igh wattage appliances and your safety is paramount SAFETY WARNINGS This controller is designed only to be used with devices that have limited power and their own thermal cut off protection such as a...

Страница 2: ...er is specially designed for high power applications Do not replace it with regular computer power cord when heating device is more than 1200 watts This controller is designed to control the devices r...

Страница 3: ...aximum current required In addition an adaptor that can convert the output socket NEMA 5 15 to the socket of local standard is needed Operating Instructions 1 Description of the controller Fig 1 Front...

Страница 4: ...nd the Timer Status Indicator 8 is lit the value displayed in the Parameter Window is time that has been passed since power up If it is flashing but Timer Status Indicator 8 is off the value displayed...

Страница 5: ...ach step contains the temperature C0X and time duration T0X setting They are represented by the symbol C0X and T0X where X is the step number e g Step 4 temperature is represented by C04 and step 4 ti...

Страница 6: ...firmed After programming the necessary steps for cooking you can finish programming by pressing the SET continuously until it passed T06 and display the current temperature You can also leave the cont...

Страница 7: ...e controller is in step 3 of cooking When 8 is on lit and 7 is flashing at the same time LED is in timer mode and shows the actual time passed since the controller was last powered up Please note that...

Страница 8: ...efficiently it transfers heat For example consider the difference between a heat lamp and a hot plate When electricity is applied to a heat lamp it begins to heat instantaneously and when it s turned...

Страница 9: ...ash alternately between A and the current water bath temperature which indicates auto tuning is in progress When the display stops flashing the auto tuning is finished Now the newly calculated PID par...

Страница 10: ...when changing the temperature unit to Fahrenheit I Integral time The unit is in seconds This parameter controls the output of controller based on the difference between the measured and set temperatu...

Страница 11: ...in to confirm the change The display will show the d for a second and its value next Use the same P setting procedure to set the d value When finished press the SET again to confirm the change The nex...

Страница 12: ...mized temperature control system should consume about 25 of the heater power at set temperature steady state for example if you found out that only 50 watts of energy is needed to maintain the tempera...

Страница 13: ...set value Setting the output reduction The parameter window will first show OUt for a second and then its value Use and keys to change OUt value to your desired limit value and press SET Setting Celsi...

Страница 14: ...not cover damage caused by misuse abuse negligent handling or damage due to faulty packaging or mishandling in transit This warranty does not cover damage or defects caused by or resulting from damag...

Страница 15: ...the package as damage in shipping is not covered by your warranty Mark the outside of your package ATTENTION CUSTOMER SERVICE We are constantly striving to improve our products and therefore the speci...

Страница 16: ...e about 1 3 watts of heat When 12 Amp is passing through the controller 16 watt of heat is produced in the controller As more heat is produced the temperature inside the controller will rise If it rea...

Страница 17: ...e current is much lower making heat not an issue 2 Limit maximum output power If you set output reduction parameter to 80 then a 15 A heater will become a 12 A heater It will take 25 longer time to he...

Страница 18: ...connected to the power strip by the 16 AWG power cord supplied blue arrows The generator is connected to the power strip by the power cord from Bradley green arrows The controller output is connected...

Страница 19: ...wer jumper cord provided by the Bradley blue arrows It is the cord that used to connect the generator to smoker The controller output is connected to the smoker by the power cord that came with contro...

Страница 20: ...ble This is especially the problem for the Bradley Original Smoker because of its black color The controller should be placed away from direct sun light also Although the controller uses a high intens...

Страница 21: ...lock the hot air from going up e Operating the controller when ambient temperature is below 32F 0C The controller reading is only accurate for temperature 32 F 0 C In addition if the ambient temperatu...

Отзывы: