THOMSON Electrak GX Скачать руководство пользователя страница 1

Thomson Electrak

®

 GX

Electric Linear Actuator

Installation Manual

Edition 2022-02

www.thomsonlinear.com

Содержание Electrak GX

Страница 1: ...Thomson Electrak GX Electric Linear Actuator Installation Manual Edition 2022 02 www thomsonlinear com...

Страница 2: ...as to the suitability of the product for any particular use or purpose For a copy of the entire warranty for this product that is contained in our standard terms and conditions of sale please go to h...

Страница 3: ...roduct identification and product label 6 4 2 Terminology 6 4 3 Operation environment 7 4 4 Mechanical installation 7 4 5 Electrical installation 10 5 Technical specifications 13 5 1 General specifica...

Страница 4: ...inal packaging supplied by Thomson The temperature during transportation and storage must be between 25 to 65 C 15 to 150 F Avoid shocks to the package If the package is damaged check the actuator for...

Страница 5: ...faulty or damaged in any way and notify an appropriate person so that corrective actions can be taken Never open the actuator as that will compromise the sealing and the function of the actuator Ther...

Страница 6: ...gnation of the actuator s in question 4 1 2 Units with product label These units have a product label on the the cover tube The label details which model of actuator you have its basic performance dat...

Страница 7: ...uator should be considered to ensure it does not create harm 4 4 2 Basic installation considerations 1 Only mount the actuator using the holes in the front and rear adapters Identify the model designa...

Страница 8: ...axially 4 4 4 Restraining torque The rear and the front adapter must be fixed by a method that can restrain the torque produced by the extension tube which for Electrak GX is 11 3 Nm 100 lbf in If not...

Страница 9: ...wind input hexagon socket a using a 6 mm hexagon key b 4 The maximum torque required to move the extension tube at the fully rated actuator load using the hand wind is typically 1 5 2 5 Nm 13 22 in l...

Страница 10: ...r leads and the power source must be of sufficient size The sufficient size is determined by calculations based on the supply voltage current draw length of the cables ambient temperature and local re...

Страница 11: ...L1 When reaching the mechanical end of stroke in any direction the built in slip clutch will engage and thus stop the extension tube movement in that direction The clutch can also be engaged during mi...

Страница 12: ...ctive of the reason 4 6 6 Installation of the feedback potentiometer optional feature The potentiometer output has 0 ohm between grey and yellow leads when the actuator is fully extended Electrical Sp...

Страница 13: ...5 max dynamic load motor auto reset thermal switch Weight Ordering stroke S in 2 4 6 8 10 12 14 16 18 20 22 24 Weight acme screw models kg 4 4 4 6 4 8 5 0 5 1 5 3 5 5 5 6 5 8 5 9 6 1 6 2 lbf 9 7 10 1...

Страница 14: ...torque Nm lbf in 11 3 100 Protection class static Dxxx xxx5 xxMxN Dxxx xxx5 xxMxK IP66 IP66 and IP69K Electrical Specifications Input voltage D12 D24 D36 D48 D90 Vdc 12 24 36 48 90 Input voltage tole...

Страница 15: ...12 0 60 0 47 15 11 0 60 043 15 9 0 60 0 35 Stroke S length Axxx xxx5 06 Axxx xxx5 08 Axxx xxx5 10 Axxx xxx5 12 Axxx xxx5 14 Axxx xxx5 16 Axxx xxx5 18 Axxx xxx5 20 Axxx xxx5 22 Axxx xxx5 24 in 6 8 10 1...

Страница 16: ...mm 06 6 inch 152 4 mm 08 8 inch 203 2 mm 10 10 inch 254 0 mm 12 12 inch 304 8 mm 14 14 inch 355 6 mm 16 16 inch 406 4 mm 18 18 inch 457 2 mm 20 20 inch 508 0 mm 22 22 inch 558 8 mm 24 24 inch 609 6 mm...

Страница 17: ...k GX 3 400 Vac 1100 N acme 30 mm s A42C20A5 Electrak GX 3 400 Vac 1100 N acme 15 mm s A42C05B5 Electrak GX 3 400 Vac 1100 N ball 61 mm s A42C10B5 Electrak GX 3 400 Vac 2250 N ball 30 mm s A42C20B5 Ele...

Страница 18: ...anstad Phone 46 44 590 2400 Fax 46 44 590 2585 E mail sales scandinavia thomsonlinear com SOUTH AMERICA Brazil Thomson Av Jo o Paulo Ablas 2970 Jardim da Gl ria Cotia SP CEP 06711 250 Phone 55 11 4615...

Отзывы: