background image

         AUBER INSTRUMENTS

  

 

 

 

 

 

 

 

         

WWW.AUBERINS.COM  

 

 

         2018.08                                                                    

   

                                                              P7/14 

 

heater. The more foams there is, the easier it is to boil over. The vigorous the 
boil is, the easy it is to boil over. To preventing the boiling over, operator should 
skim the foam out and reduce the power as the temperature approaching the 
boiling.    Since  the  heater  power  and  liquid  volume  varies  between  each 
application, we suggest the bAST to be set at least 5 degree (Fahrenheit) below 
the boiling point for the first time use. As you getting familiar with your system, 
you can change this setting to higher or lower.  The bOUT is the power used 
during initial heating phase. The unit is in percent of power. It should be set to 
100% unless you have a very powerful heater with very small amount of liquid. 
The bOUT setting does not limit the power regulation range for boiling phase. 

If 

you don’t need to use this feature, set bAST 

to 0, so this controller will 

work as a manual mode controller over the entire temperature range. 

 

Note 8:

 

Timer and event settings (boil mode): nE, bot1 ~ bot9 

A timer event is defined as an action of adding an ingredient at a specific time 
point during the wort boiling process. An event timer starts from the moment that 
the ingredient is being added to the wort; it stops when the wort-boiling process 
comes to an end. There can be multiple events during the wort-boiling process. 
Each event should have a different starting time point, but they all end at the 
same time, which is when the boiling process ends.  
 
To start activate the timer event, you need to 1) change the timer status from 

“stop” to “run” by pressing Key A momentarily. 2) the reading temperature must 

be higher than bTSP (section 6.3, note 9). When the timer starts, the top display 
will show the reading temperature and total the remaining time (before the end 
of  last  event)  alternately.  The  temperature  and  time  display  can  be  easily 
differentiated with their appearance. The temperature reading has two or three 

digits. For example, 212 degrees will be displayed as “212”. The timer display 

has four digits with fl

ashing colon in the middle. For example, “01:20” for 1 hour 

20  minutes.  The  bottom  display  will  show  the  power  output  percentage  and 
current step number (e.g. P-1 for step 1) alternately. 
 
Please see Figure 9 for a schematic diagram showing the relationship between 
multiple events and the alarm relay status.     
 

nE, 

total number of timer events.

 

An event can be associated with an activity 

such has adding hops or special ingredients. Each event has its own timer. 

nE

 

can be set to a number from 1 to 9. The built-in buzzer will be triggered at the 
beginning of all events except the first event, and at the end of the entire boiling 
process. So 

nE

 is equal to the total number of times you want the buzzer to ring. 

You can also set the external relay synchronized with the built-in buzzer (section 
6.4.2, note 12). For example, if you only add one hop at the very beginning of 
the  boiling  process,  and  add  another  hop  in  the  middle  of  boiling,  which  is 
considered as the second event, you need to set nE = 2, and the buzzer will go 
off when the second even starts. 
 

Event timer

: botX (i.e. bot1, bot2, bot3, …, bo

tX), 

the time duration of each 

event, where 

X

 is the event number (1 ~ 9). 

X

 is decided by parameter 

nE

. Time 

duration of an event, 

botX

, is the boiling time of an ingredient to be added to the 

boiling wort. 

bot1

 is the first event timer which starts from the moment that the 

first ingredient is added until the end of boiling, 

bot2

 is the second event timer 

which starts when the second ingredient is added until the end of boiling, and so 
on.  The  buzzer  will  be  triggered  at  the  beginning  of  all  event  timers  (

bot1

bot2

, …, 

bot9

). The buzzer will be also triggered when all the event timers are 

ended.  
 
An event timer that starts later should be no longer then the event timers that 
start earlier, i.e., 

bot1

 

≥ 

bot2

 

≥ 

bot3

 

≥ …≥ 

botX

. When an event timer is equal 

to its prior event timer, this event timer will be ignored. For example, if you set 

bot1

 = 

bot2

, timer 

bot2

 will be ignored.   

 
Example: If the first ingredient (bot1) needs 60 minutes, the second ingredient 
(bot2) needs 10 minutes and third ingredient (bot3) needs 1 minutes of boil, you 
set Bot1 = 1:00, Bot2 = 00:10, Bot3 = 00:01. Assuming the timer will start at 0 
minute (add first ingredient here). 50th minute from the beginning, controller will 
beep  and  let  you  add  second  ingredient.  59th  minute  from  the  beginning, 
controller will beep again to remind you it is the time to add the third ingredient. 

 

 

Figure 9. A schematic diagram of how the event timers and built-in buzzer work 
(nE = 3).    

 

Note 9: Boiling mode timer function: tF, btSP, bEO 
tF

.  The 

timer  event  function  (for  boil  mode)

  is  controlled  by  a  master 

parameter 

tF

.  When it is set to 

ON

, the timer event function for boiling mode is 

enabled. When 

tF

 is set to 

OFF

, the timer function for boiling mode is disabled.  

When timer function is enabled, the timer counting will be started by 

timer start 

temperature, btSP

. When reading temperature reaches timer start temperature, 

the timer starts to count, and the controller will generate three short beeps. After 
timer started counting, it will continue even if the temperature drops below this 
start temperature.  The timer can be reset to start from beginning again. To reset 
the timer, press the knob momentarily, the display will show 

rSt

 on top and 

“n”

 

at the bottom, rotate the dial clockwise will change the bottom display to 

y

Press the knob again to reset the timer. 
 
When time counting ends, the controller will generate  eight long beeps. Both 
displays will flash 

End

 alternately. After timer ends, the power output can be 

configured either to continue heating, or shut off. It is controlled by the parameter 
called 

ending options for boiling mode, bEO

. Set it to 

ON

 for continue heating, 

set it to 

OFF

 to turn off the output.  

 
 

goto

boil

Knob

bast

200

Knob

bout

100

Knob

ne

3

Knob

bot1

01

:

00

Knob

bot2

00

:

20

Knob

80

100

Knob

Press

Press

Press

Press

Press

Press

Press

Boil acceleration 

set temp.

Boil 

acceleration 

output power

Total numbers of 

timer events

Event 1 timer

Event 2 timer 

Event 3 timer

tf

on

Boil timer 

start temp. 

Knob

beo

off

Knob

ad

10

Knob

btsp

208

Knob

Press

Press

Press

Press

Alarm duration 

for boil mode

Boil 

ending option

Timer function 

for boil mode

bot3

00

:

01

End

 

 

Figure 10. Flow chart for boiling mode settings 

 

Содержание EZboil DSPR310D

Страница 1: ...n 2 seconds after you stop the adjustment 4 AL1 indicator This red LED indicates the status of Relay 1 AL1 When it is on relay 1 is closed when it is off relay 1 is open 5 AL2 indicator This red LED indicates the status of Relay 2 AL2 When it is on relay 2 is closed when it is off relay 2 is open 6 Mashing mode indicator MASH This yellow LED light indicates the operation mode of the controller Whe...

Страница 2: ...ep mashing control or boiling control mode Press the knob will set the controller to the operation mode displayed Please check section 5 1 for details Display mode 3 Parameter settings Press down and hold the knob for 5 seconds to enter the display mode 3 Please check section 6 for details 5 Operation 5 1 Operation mode selection This controller offers two operation modes step mashing and boiling ...

Страница 3: ...ashing temperature steps User can selectively turn on or off the relay s at specific steps These relays can also be programmed to be synchronized with the internal beeper so that external buzzer can be used for notification at the beginning and end of each step see section 6 4 2 note 12 5 2 4 Adjusting parameter value Two ways to adjust set temperature 1 To adjust the set temperature in current st...

Страница 4: ...ettings Knob Press Knob Press Rotate Knob Rotate Knob Knob Press goto rely Enter Relay settings Knob Press Rotate Knob goto syst Enter System settings Knob Press Rotate Knob Figure 5 Parameter group selection Tip 1 When timer is started you will hear the beeping notification Please see section 9 in page 10 for details Tip 2 Similar to mashing mode you can even hold the timer by pressing key B mome...

Страница 5: ... alternately In other word the timer for step mashing mode is countdown timer Note 4 Timer Function tSP EO When the program is end please check section 5 2 2 for the difference between end and stop the controller will generate six long beeps The top display will switch between the current temperature and End alternately After timer ends the power output can be configured either to continue heating...

Страница 6: ...to prog Knob C 1 122 Knob T 2 00 20 Knob C 8 50 Knob 80 100 Knob T 8 00 00 Step 1 set temp Step 2 time duration Step 8 set temp End Press Press Press Press Press T 1 00 30 Knob C 2 140 Knob Step 1 time duration Step 2 set temp Press Press Step 8 time duration Figure 8 Flow chart of setting step program settings 6 3 Boiling Parameters Parameters the configure the boiling control are grouped under t...

Страница 7: ...2 and the buzzer will go off when the second even starts Event timer botX i e bot1 bot2 bot3 botX the time duration of each event where X is the event number 1 9 X is decided by parameter nE Time duration of an event botX is the boiling time of an ingredient to be added to the boiling wort bot1 is the first event timer which starts from the moment that the first ingredient is added until the end o...

Страница 8: ...N this relay can be programmed to be activated at target boiling step or steps Parameter rLP is used for programming see below Beep In this mode relay is synchronized with internal buzzer When the built in buzzer beeps this relay also turns on This will allow the user to drive an external flashing buzzer for louder and visual notification ALbE Alarm and beep mode Take relay 1 as an example relay 2...

Страница 9: ...re determined period of time User can set the pulse duration by the AP parameter in the menu of alarm settings it ranges from 1 to 100 seconds This feature is useful in situations where a user only need to ring the buzzer for a short time or want to drive an external load for a fixed amount of time duration When LAt it is set to N Non Latching rL ALM ALbE only the relay action will follow the alar...

Страница 10: ...g diagrams of how to connect a DC triggered AC SSR with this power regulator SSR 1 2 3 13 14 6 7 8 9 10 4 5 RTD R R W 120V AC L N Heater 3 4 SSR 3 4 1 2 3 13 14 6 7 8 9 10 4 5 RTD R R W Heater 240V AC L1 L2 Figure 13 Wiring examples of controlling a heater with SSR and DSPR310D in a 120VAC system upper and in a 240VAC system lower Example 2 Here is the wiring diagram of how to wire two external bu...

Страница 11: ...essage or incorrect temperature reading if your sensor is not connected or your sensor is bad Top display will flash orAL and 932 alternately if you set it to Fahrenheit display C F F or orAL and 500 alternately if you set it to Celsius display C F C Auber Instruments 5755 North Point Parkway Suite 99 Alpharetta GA 30022 www auberins com Email info auberins com Tel 770 569 8420 Copyright 2007 2018...

Страница 12: ...ower Figure 5 Original AC sine wave is overlaid with SSVR output wave form The blue colored area shows the power output that has been blocked 2 Time proportional firing A fixed cycle time needs to be defined in this method Then the controller or regulator adjusts the on time during each cycle to achieve the power control For example if the cycle time is 1 second turn on the power for 0 25 second f...

Страница 13: ...al drop to zero the AC power is blocked 3 Burst firing This method is similar to time proportional firing section 2 But in contrast to the time proportional mode where the SSR is fired once for each fixed cycle period which are usually 2 seconds or longer the regulator will find the minimum cycle time to achieve the desired output percentage The on pulse can be as short as one AC cycle So power is...

Страница 14: ... DSPR detects the frequency and phase of the AC power line so that the pulse width and firing time is synchronized with AC cycle Auber Instruments 5755 North Point Parkway Suite 99 Alpharetta GA 30022 www auberins com Email info auberins com Tel 770 569 8420 Copyright 2007 2018 Auber Instruments All Rights Reserved No part of this manual shall be copied reproduced or transmitted in any way without...