background image

         AUBER INSTRUMENTS

  

 

 

 

 

 

 

 

         

WWW.AUBERINS.COM  

 

 

         2018.08                                                                    

   

                                                              P2/14 

 

described later, we suggest you connect the hot wire to terminal 10 and neutral 
to 9. 
 

3.3 SSR output connection 

The SSR control output of the DSPR310D provides a 12 VDC signal that can 
control up to 5 SSRs in parallel. Connect terminal 7 to the positive pole of the 
SSR (terminal 3 on 

Auber’s SSR

s). Connect terminal 6 to the negative pole of 

the SSR (terminal 4 on Auber

’s

 SSRs). Please make sure the SSR is installed 

on the heat sink with proper current rating. 
 

4.

 

Display Status 

  

Power on

80

100

Display mode 1

rst

n

Display mode 2

Mash

Parameter settings

Display mode 3

Next parameter

goto

Timer reset / 

mode selection

Knob

Press

Knob

Knob

Press down and 

Hold for 5s

Press

Exit

Exit

 

Figure 3. Display modes of DSPR310D.  

 

Display mode 1 (Normal operating mode):

 

1) When MASH indicator is ON

the  controller  is  in 

step  mashing  mode

.  The  top  display  will  show  reading 

temperature,  and  it  may  also  flash  the  remaining  time  for  the  current  step 
alternately (see section 5.2.1). The bottom display will flash set temperature in 
this  step  and  current  step  number  (e.g.  P-1  for  step  1)  alternately. 

2)  When 

MASH indicator is OFF

, the controller is in 

boiling mode

. The top display will 

show reading temperature, and it may also flash the total remaining time of timer 
events alternately (see section 5.3.1). The bottom display will flash current output 
power percentage  (e.g. P50  for 50% power output) and current step number 
alternately.  
 

Display  mode  2  (Step  program  reset  &  Operation  mode  selection):

  This 

display mode allows you to reset the timer (mashing and boiling modes), or to 
switch between the mashing and boiling operation mode.  
 
A short press of the knob will enter this display mode.  
 

1) The display will show “rSt” on top and “n” at the bott

om. This is the exit menu.  

If you enter this mode by accident, you can press the knob again to exit this 
display mode without changing anything. 
 

2) Rotate the dial clockwise for one click will change the bottom display to “y”. 

This option is to stop the program steps/timer events. Bottom display will flash 

“stop”. 

It functions the same if you press and hold the Key B for 5 seconds.  

 

3) Rotate the knob with two clicks, the top display will change to “Mode” and 
bottom will show “Mash”, which is for step ma

sh mode.  Rotate the knob again, 

the 

bottom display will change to “Boil”, which is for boil mode.

 These two menus 

are for setting the controller to either step mashing control or boiling control mode. 
Press the knob will set the controller to the operation mode displayed. Please 
check section 5.1 for details. 
 

Display mode 3 (Parameter settings):

 Press down and hold the knob for 5 

seconds to enter the display mode 3. Please check section 6 for details. 

5.

 

Operation 

5.1 Operation mode selection

 

This controller offers two operation modes, step mashing and boiling. When the 
step  mashing  mode  is  selected,  the  controller  functions  as  a  temperature 
controller  with  steps.  It  automatically  adjusts  the  power  output  to  hold  the 
temperature at set point in that step.  When boiling control mode is selected, the 
controller functions as a power regulator.  It allows the user to manually adjusting 
the power to control the strength of the boil. Figure 4 shows how to select and 
switch between these two modes. 

 

rst

n

rst

y

80

100

Knob Press

mode

mash

Rotate

mode

boil

Rotate

Knob

Step Mash 

Mode

Boil Mode

Rotate

Knob

Knob

Press

Knob

Press

Knob

Timer Reset

Knob

Press

Exit

Knob

Press

 

 

Figure 4. Flow chart for timer reset & operation mode selection. 

 

Press the knob once. The display will show 

rSt

. Rotate the knob with two clicks, 

the top d

isplay will change to “Mode” and bottom will show “

Mash*

”.  

Press the 

knob will set the controller to mashing mode. When mashing mode is selected, 
the yellow indicator on the top left corner of the panel will lit.  This indicator will 
be off if the boiling mode is selected. 
 

Note 1: due to the limitation of 7 segment LED display, 

the letter “M”

 

is displayed as “

m

”.

 

 

Note 2: if you mistakenly enter this layer of setting, you need to dial the knob to show: 

rst

n

 

Then press the knob again to exit. Nothing will be changed.  

 

5.2 Step Mashing Operation 
5.2.1 Introduction 

When first powered up, make sure the controller is in the mashing mode: The 
yellow colored mashing mode indicator on the upper left corner should be on, 

and the bottom display has no “P” on the left. If not, please change the control 

mode to mashing mode as discussed in section 5.1 above. If you were using the 
controller in the step mashing mode when powered off last time, the controller 
will start in the step mashing mode.   
 
After  controller  is  powered  up,  the  top  LED  displays  the  current  temperature 
reading  from the sensor. If temperature sensor is not connected, it will  show 

“orAL”. 

When the step mashing timer is triggered and counting down,  the top 

display will start to display the current temperature and the remaining time for 
the  current  step  alternately.  The  bottom  LED  displays  your  current  set 
temperature, and it may also flash current step status alternately

, including “run”, 

“hold” and “stop”.

   

 

Содержание EZboil DSPR310D

Страница 1: ...n 2 seconds after you stop the adjustment 4 AL1 indicator This red LED indicates the status of Relay 1 AL1 When it is on relay 1 is closed when it is off relay 1 is open 5 AL2 indicator This red LED indicates the status of Relay 2 AL2 When it is on relay 2 is closed when it is off relay 2 is open 6 Mashing mode indicator MASH This yellow LED light indicates the operation mode of the controller Whe...

Страница 2: ...ep mashing control or boiling control mode Press the knob will set the controller to the operation mode displayed Please check section 5 1 for details Display mode 3 Parameter settings Press down and hold the knob for 5 seconds to enter the display mode 3 Please check section 6 for details 5 Operation 5 1 Operation mode selection This controller offers two operation modes step mashing and boiling ...

Страница 3: ...ashing temperature steps User can selectively turn on or off the relay s at specific steps These relays can also be programmed to be synchronized with the internal beeper so that external buzzer can be used for notification at the beginning and end of each step see section 6 4 2 note 12 5 2 4 Adjusting parameter value Two ways to adjust set temperature 1 To adjust the set temperature in current st...

Страница 4: ...ettings Knob Press Knob Press Rotate Knob Rotate Knob Knob Press goto rely Enter Relay settings Knob Press Rotate Knob goto syst Enter System settings Knob Press Rotate Knob Figure 5 Parameter group selection Tip 1 When timer is started you will hear the beeping notification Please see section 9 in page 10 for details Tip 2 Similar to mashing mode you can even hold the timer by pressing key B mome...

Страница 5: ... alternately In other word the timer for step mashing mode is countdown timer Note 4 Timer Function tSP EO When the program is end please check section 5 2 2 for the difference between end and stop the controller will generate six long beeps The top display will switch between the current temperature and End alternately After timer ends the power output can be configured either to continue heating...

Страница 6: ...to prog Knob C 1 122 Knob T 2 00 20 Knob C 8 50 Knob 80 100 Knob T 8 00 00 Step 1 set temp Step 2 time duration Step 8 set temp End Press Press Press Press Press T 1 00 30 Knob C 2 140 Knob Step 1 time duration Step 2 set temp Press Press Step 8 time duration Figure 8 Flow chart of setting step program settings 6 3 Boiling Parameters Parameters the configure the boiling control are grouped under t...

Страница 7: ...2 and the buzzer will go off when the second even starts Event timer botX i e bot1 bot2 bot3 botX the time duration of each event where X is the event number 1 9 X is decided by parameter nE Time duration of an event botX is the boiling time of an ingredient to be added to the boiling wort bot1 is the first event timer which starts from the moment that the first ingredient is added until the end o...

Страница 8: ...N this relay can be programmed to be activated at target boiling step or steps Parameter rLP is used for programming see below Beep In this mode relay is synchronized with internal buzzer When the built in buzzer beeps this relay also turns on This will allow the user to drive an external flashing buzzer for louder and visual notification ALbE Alarm and beep mode Take relay 1 as an example relay 2...

Страница 9: ...re determined period of time User can set the pulse duration by the AP parameter in the menu of alarm settings it ranges from 1 to 100 seconds This feature is useful in situations where a user only need to ring the buzzer for a short time or want to drive an external load for a fixed amount of time duration When LAt it is set to N Non Latching rL ALM ALbE only the relay action will follow the alar...

Страница 10: ...g diagrams of how to connect a DC triggered AC SSR with this power regulator SSR 1 2 3 13 14 6 7 8 9 10 4 5 RTD R R W 120V AC L N Heater 3 4 SSR 3 4 1 2 3 13 14 6 7 8 9 10 4 5 RTD R R W Heater 240V AC L1 L2 Figure 13 Wiring examples of controlling a heater with SSR and DSPR310D in a 120VAC system upper and in a 240VAC system lower Example 2 Here is the wiring diagram of how to wire two external bu...

Страница 11: ...essage or incorrect temperature reading if your sensor is not connected or your sensor is bad Top display will flash orAL and 932 alternately if you set it to Fahrenheit display C F F or orAL and 500 alternately if you set it to Celsius display C F C Auber Instruments 5755 North Point Parkway Suite 99 Alpharetta GA 30022 www auberins com Email info auberins com Tel 770 569 8420 Copyright 2007 2018...

Страница 12: ...ower Figure 5 Original AC sine wave is overlaid with SSVR output wave form The blue colored area shows the power output that has been blocked 2 Time proportional firing A fixed cycle time needs to be defined in this method Then the controller or regulator adjusts the on time during each cycle to achieve the power control For example if the cycle time is 1 second turn on the power for 0 25 second f...

Страница 13: ...al drop to zero the AC power is blocked 3 Burst firing This method is similar to time proportional firing section 2 But in contrast to the time proportional mode where the SSR is fired once for each fixed cycle period which are usually 2 seconds or longer the regulator will find the minimum cycle time to achieve the desired output percentage The on pulse can be as short as one AC cycle So power is...

Страница 14: ... DSPR detects the frequency and phase of the AC power line so that the pulse width and firing time is synchronized with AC cycle Auber Instruments 5755 North Point Parkway Suite 99 Alpharetta GA 30022 www auberins com Email info auberins com Tel 770 569 8420 Copyright 2007 2018 Auber Instruments All Rights Reserved No part of this manual shall be copied reproduced or transmitted in any way without...

Отзывы: