background image

  AUBER INSTRUMENTS

    

 

 

     

 

 

 

             

WWW.AUBERINS.COM  

 

2018.08                                                                                                                                                                                                          P1/13

 

                 

                                                                                                                          

EZboil for Step Mashing and Boiling Process Automation, DSPR310D 

Version 1.1 (Aug, 2018) 

 

 

Caution

  

 

This  controller  is  intended  to  control  equipment  under  normal  operating 
conditions.  Failure  or  malfunction  of  the  controller  may  lead  to  abnormal 
operating  conditions,  which  result  in  personal  injury  or  damage  to  the 
equipment  or  other  property.  Devices  (limit  or  safety  controls)  or  systems 
(alarm  or  supervisory)  intended  to  warn  of  or  protect  against  failure  or 
malfunction of the controller must be incorporated into and maintained as part 
of the control system. 

 

Installing the rubber gasket supplied will protect the controller front panel from 
dust and water splash (IP54 rating). Additional protection is needed  for higher 
IP rating. 

 

This  controller  carries  a  90-day  warranty.  This  warranty  is  limited  to  the 
controller only. 

 

1.

 

Specifications 

Input type 

RTD (Resistance Temperature Detector): Pt100 

Accuracy 

±  0.2% full scale 

Temperature 
range 

-328° F ~ +932° F, -200° C ~ +500° C 

Response time 

 0.5s 

Display 
resolution 

1° C or ° F 

Control mode 

Step Mashing, Boiling 

Program step 

Up to 8 program steps for mashing mode 
Up to 9 timer events for boiling mode 

Timer range 

Up to 99h for each step/event 

Relay output 

Relay contact: 3A for resistive load. 1A for inductive 
load 

Power supply 

85~260 VAC/50~60 Hz 

Power 
consumption 

 5 Watt 

Working Ambient 
temperature 

0~50ºC, 32~122ºF 

Dimension 

48 x 48 x 100 mm (W x H x D, from the front panel to 
the back) 

Mounting cutout 

45 x 45 mm 

 

2.

 

Front Panel 

8

5

4

1

2

3

7

6

9

 

Figure 1. The front panel of DSPR310D. 

1). Top display.

 This display indicates the temperature sensor readout value. it 

may also show time and temperature alternately. (see section 4) 

2). Bottom display.

 In boiling mode, this display will show the percentage of 

power being sent to the external SSR after the initial heat up phase. In mashing 
mode, this display will show the set temperature. It may also flash step number 
alternately under these two modes. (see section 4) 

3). Temperature setting adjusting indicator.

 This is the small dot at the lower 

right corner. In mashing mode, when temperature set point is adjusted, it will 
start  to  flash.  It  reminds  you  that  you  need  to  press  the  knob  to  confirm  the 
change. Otherwise, the temperature setting will return back in 2 seconds after 
you stop the adjustment.  

4). AL1 indicator

. This red LED indicates the status of Relay 1 (AL1). When it 

is on, relay 1 is closed; when it is off, relay 1 is open. 

5). AL2 indicator

. This red LED indicates the status of Relay 2 (AL2). When it 

is on, relay 2 is closed; when it is off, relay 2 is open. 

6).  Mashing  mode  indicator  (MASH). 

This  yellow  LED  light  indicates  the 

operation mode of the controller. When it is on, controller is in mashing mode; 
when it is off, controller is in boiling mode.  

7).  Output  indicator  (OUT).

  This  green  LED  light  is  SSR  output  indicator.  It 

shows how much power the regulator is sending out (as a 12VDC control signal 
pulse through terminal 6 and 7). When it is solid ON, the output is 100% on. 
When it is off, there is no output. When it is flashing, the frequency of the flashing 
is  an  indication  of  high  or  low  power  output.  Higher  frequency  means  higher 
power output percentage.  

8). Rotary switch (knob).

 Turn it clockwise to increase the output power (or 

selected parameter value); turn it counter-clockwise to reduce the output power 
(or selected parameter value). Press it momentarily to reset the timer (if enabled) 
and  to  switch  between  mashing  and  boiling  mode.  Press  and  hold  it  for  5 
seconds to enter parameter settings menu. (see section 6) 

9). Program Function Key A & B.

 There are two function k

eys named “A” 

(or 

“RUN”) and “B”

 

(or “HOLD/STOP”)

. Key A can be used to start or resume the 

program (step mashing mode) or power output/timer (boiling mode). Key B can 
be used to hold or stop the program or timer. Please see section 5.2.2 and 5.3.3. 
Key A can also be used to mute the built-in buzzer in specific situations. Please 
refer to section 5.3.3 for more details.  
 

3.

 

Wiring Terminals 

The pin assignment of the back terminals of DSPR310D is shown in Figure 2.  

1
2
3

13 14 6

7
8
9

10

4
5

AL1

AL2

AC

85~260V

SSR

+

-

RTD

R

R

W

 

Figure 2. Terminal assignments of DSPR310D.  

 

3.1 Sensor connection 

DSPR310D only accepts Pt100 RTD temperature sensor. For a three-wire RTD 
with  standard  DIN  color  code,  the  two  red  wires  should  be  connected  to  the 
terminals 3 and 4. The white wire should be connected to terminal 5. For a two-
wire RTD, the wires should be connected to terminals 4 and 5. Jump  a wire 
between terminals 3 and 4.  
 

3.2 Power to the controller 

The power cables should be connected to terminals 9 and 10. Polarity does not 
matter. It can be powered by 85-260 VAC power source. Neither a transformer 
nor jumper is needed to wire it up. For the consistent with the wiring example 

Instruction Manual

 

 

Содержание EZboil DSPR310D

Страница 1: ...n 2 seconds after you stop the adjustment 4 AL1 indicator This red LED indicates the status of Relay 1 AL1 When it is on relay 1 is closed when it is off relay 1 is open 5 AL2 indicator This red LED indicates the status of Relay 2 AL2 When it is on relay 2 is closed when it is off relay 2 is open 6 Mashing mode indicator MASH This yellow LED light indicates the operation mode of the controller Whe...

Страница 2: ...ep mashing control or boiling control mode Press the knob will set the controller to the operation mode displayed Please check section 5 1 for details Display mode 3 Parameter settings Press down and hold the knob for 5 seconds to enter the display mode 3 Please check section 6 for details 5 Operation 5 1 Operation mode selection This controller offers two operation modes step mashing and boiling ...

Страница 3: ...ashing temperature steps User can selectively turn on or off the relay s at specific steps These relays can also be programmed to be synchronized with the internal beeper so that external buzzer can be used for notification at the beginning and end of each step see section 6 4 2 note 12 5 2 4 Adjusting parameter value Two ways to adjust set temperature 1 To adjust the set temperature in current st...

Страница 4: ...ettings Knob Press Knob Press Rotate Knob Rotate Knob Knob Press goto rely Enter Relay settings Knob Press Rotate Knob goto syst Enter System settings Knob Press Rotate Knob Figure 5 Parameter group selection Tip 1 When timer is started you will hear the beeping notification Please see section 9 in page 10 for details Tip 2 Similar to mashing mode you can even hold the timer by pressing key B mome...

Страница 5: ... alternately In other word the timer for step mashing mode is countdown timer Note 4 Timer Function tSP EO When the program is end please check section 5 2 2 for the difference between end and stop the controller will generate six long beeps The top display will switch between the current temperature and End alternately After timer ends the power output can be configured either to continue heating...

Страница 6: ...to prog Knob C 1 122 Knob T 2 00 20 Knob C 8 50 Knob 80 100 Knob T 8 00 00 Step 1 set temp Step 2 time duration Step 8 set temp End Press Press Press Press Press T 1 00 30 Knob C 2 140 Knob Step 1 time duration Step 2 set temp Press Press Step 8 time duration Figure 8 Flow chart of setting step program settings 6 3 Boiling Parameters Parameters the configure the boiling control are grouped under t...

Страница 7: ...2 and the buzzer will go off when the second even starts Event timer botX i e bot1 bot2 bot3 botX the time duration of each event where X is the event number 1 9 X is decided by parameter nE Time duration of an event botX is the boiling time of an ingredient to be added to the boiling wort bot1 is the first event timer which starts from the moment that the first ingredient is added until the end o...

Страница 8: ...N this relay can be programmed to be activated at target boiling step or steps Parameter rLP is used for programming see below Beep In this mode relay is synchronized with internal buzzer When the built in buzzer beeps this relay also turns on This will allow the user to drive an external flashing buzzer for louder and visual notification ALbE Alarm and beep mode Take relay 1 as an example relay 2...

Страница 9: ...re determined period of time User can set the pulse duration by the AP parameter in the menu of alarm settings it ranges from 1 to 100 seconds This feature is useful in situations where a user only need to ring the buzzer for a short time or want to drive an external load for a fixed amount of time duration When LAt it is set to N Non Latching rL ALM ALbE only the relay action will follow the alar...

Страница 10: ...g diagrams of how to connect a DC triggered AC SSR with this power regulator SSR 1 2 3 13 14 6 7 8 9 10 4 5 RTD R R W 120V AC L N Heater 3 4 SSR 3 4 1 2 3 13 14 6 7 8 9 10 4 5 RTD R R W Heater 240V AC L1 L2 Figure 13 Wiring examples of controlling a heater with SSR and DSPR310D in a 120VAC system upper and in a 240VAC system lower Example 2 Here is the wiring diagram of how to wire two external bu...

Страница 11: ...essage or incorrect temperature reading if your sensor is not connected or your sensor is bad Top display will flash orAL and 932 alternately if you set it to Fahrenheit display C F F or orAL and 500 alternately if you set it to Celsius display C F C Auber Instruments 5755 North Point Parkway Suite 99 Alpharetta GA 30022 www auberins com Email info auberins com Tel 770 569 8420 Copyright 2007 2018...

Страница 12: ...ower Figure 5 Original AC sine wave is overlaid with SSVR output wave form The blue colored area shows the power output that has been blocked 2 Time proportional firing A fixed cycle time needs to be defined in this method Then the controller or regulator adjusts the on time during each cycle to achieve the power control For example if the cycle time is 1 second turn on the power for 0 25 second f...

Страница 13: ...al drop to zero the AC power is blocked 3 Burst firing This method is similar to time proportional firing section 2 But in contrast to the time proportional mode where the SSR is fired once for each fixed cycle period which are usually 2 seconds or longer the regulator will find the minimum cycle time to achieve the desired output percentage The on pulse can be as short as one AC cycle So power is...

Страница 14: ... DSPR detects the frequency and phase of the AC power line so that the pulse width and firing time is synchronized with AC cycle Auber Instruments 5755 North Point Parkway Suite 99 Alpharetta GA 30022 www auberins com Email info auberins com Tel 770 569 8420 Copyright 2007 2018 Auber Instruments All Rights Reserved No part of this manual shall be copied reproduced or transmitted in any way without...

Отзывы: